MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s13239-019-00443-0

Медицинская библиотека · Cardiovascular engineering and technology · 2019

Hemodynamic Effects of Multiple Overlapping Uncovered Stents on Aortic Dissection: Surgical Strategies and Implications for False Lumen Thrombosis.

Dai Yanan, Luo Guangze, Dai Xiangchen, Liu Haofei

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Multiple overlapping uncovered stents (MOUS) are employed to promote false lumen thrombosis in the aortic dissections (AD), when the tears are in close vicinity to the branch vessels. However, the overall rate of false lumen thrombosis remains unsatisfactory. This study was performed to investigate the hemodynamic influence of MOUS on aortic dissection to shed some light on the mechanism of post-stenting false lumen thrombosis.

METHODS

An anatomically accurate computational fluid dynamics model was developed to investigate the hemodynamics of AD. A parametric study was carried out to demonstrate the hemodynamic influence of MOUS in various post-surgery scenarios featuring the representative surgical strategies involving MOUS.

RESULTS

The use of reduced-porosity MOUS slowed the blood flow in the false lumen and decreased the wall shear stress. MOUS depressed the false lumen and enlarged the true lumen, without significantly altering the blood outflow distribution among the branch vessels. Compared with MOUS-alone and stent graft-alone scenarios, the combination of MOUS and stent graft generated a substantially large region of stagnant flow. The active flow was confined to an area in close vicinity to the tears covered by the MOUS, which perfuse the right renal artery in the false lumen.

CONCLUSIONS

MOUS helps to generate a favored hemodynamic environment for thrombus formation in the false lumen. Application of MOUS along with covered stent grafts may represent a more effective treatment for AD than utilizing MOUS or stent graft alone.

Для цитирования: Dai Yanan, Luo Guangze, Dai Xiangchen, Liu Haofei. Hemodynamic Effects of Multiple Overlapping Uncovered Stents on Aortic Dissection: Surgical Strategies and Implications for False Lumen Thrombosis.. Cardiovascular engineering and technology. 2019. DOI: 10.1007/s13239-019-00443-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.