Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2017

Contact-force-guided vs. contact-force-blinded catheter ablation of typical atrial flutter: a prospective study.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Venier Sandrine, Andrade Jason G, Khairy Paul, Mondésert Blandine, Dyrda Katia, Rivard Léna, Guerra Peter G, Dubuc Marc, Thibault Bernard, Talajic Mario, Roy Denis, Macle Laurent

Аннотация

AIMS: It remains unknown whether contact force (CF) sensing technology is of value for cavotricuspid isthmus (CTI) ablation. We prospectively evaluated procedural parameters and outcomes of CF-guided vs. CF-blinded CTI ablation for typical atrial flutter (AFL).

METHODS AND RESULTS: A total of 70 consecutive patients (62.5 ± 10.9 years) undergoing CTI ablation for AFL were prospectively enrolled, 35 in CF-blinded and 35 in CF-guided groups. A CF-sensing catheter (power 25-35 W) was used in all. In the CF-guided group, CF target range was 10-25 g, whereas in the CF-blinded group, the operator was blinded to CF. The isthmus was divided into anterior, middle, and posterior segments for region-specific CF analysis. The procedural endpoint of bidirectional isthmus block following a 20-min observation period was achieved in all. A trend towards lower fluoroscopy and procedure duration was observed when the CF-guided group was compared with the CF-blinded group. The total radiofrequency (RF) energy delivery time required to achieve bidirectional block was significantly lower in the CF-guided vs. CF-blinded group [10.0 min (IQR 8.3;15.1) vs. 15.9 min (IQR 9.6;24.7), P= 0.0020], with a significant inverse correlation between CF and total RF delivery time (r = -0.36; P= 0.0027). Mean CF measurements significantly increased from anterior to posterior anatomical zones of CTI in the CF-blinded group (ANOVA P= 0.0466).

CONCLUSIONS: Catheter ablation of AFL guided by real-time CF assessment results in a significant reduction in total RF delivery time. Real-time CF measurements facilitate the maintenance of homogenous efficient contact all along the CTI, particularly in the anterior segment where CF is generally lower.