MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lsm.23594

Медицинская библиотека · Lasers in surgery and medicine · 2022

Comparison of the safety and efficacy of low fluence Q-switched 1064-nm and conventional Q-Switched 755-nm lasers in the treatment of café-au-lait macules: A prospective self-controlled trial.

Cen Qingqing, Zhu Jiafang, Zhou Lucia, Yu Wenxin, Wu Xianglei, Liu Ying, Ma Gang, Luo Lan, Lin Xiaoxi

Контролируемое клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Conventional high fluence Q-switched (HFQS) Alexandrite 755-nm are widely used in clinical café-au-lait macules (CALMs) treatment. There have been recent concerns regarding the efficacy and safety of low fluence Q-switched (LFQS) Nd: YAG 1064-nm lasers.

OBJECTIVE

To evaluate the efficacy and safety of the conventional HFQS and LFQS laser in the treatment of CALMs.

METHODS

Within 3 months, 20 patients underwent prospective self-controlled split-lesion treatments with HFQS once or twice depending on the recovery rate, and with LFQS six times biweekly. Then the more effective laser was selected for continued treatments. Efficacy outcomes were evaluated by a visual analog scale (VAS) biweekly during the comparative trail. Recovery process, side effects and recurrence were recorded during the trial and follow-up visit. Patient and physician preferences for laser selection were also recorded.

RESULTS

The average VAS scores of areas treated with HFQS and LFQS were 2.92 ± 0.86 and 2.93 ± 1.13, respectively (p > 0.05). The most significant efficacy change of LFQS was after the fourth laser treatment (VAS score: 1.82-2.37, p < 0.001). 11 lesions treated with LFQS and 7 with HFQS achieved an optimal treatment response (3.67 ≤ VAS ≤ 4). Three patients relapsed on one side (one on LFQS, two on HFQS) and five on both sides. Adverse effects included temporary hypopigmentation, hyperpigmentation, uneven pigmentation, and mottled hypopigmentation. Doctors thought 80% of patients were suitable for LFQS. 70% of patients preferred LFQS posttreatment.

CONCLUSIONS

The efficacy difference between the LFQS 1064-nm laser and HFQS 755-nm laser in treating CALMs in a 3-month comparative trial was statistically insignificant. LFQS is preferred by doctors and patients and is likely to help more patients achieve treatment efficacy than the HFQS within a short time, with fewer temporary adverse reactions, and a more even pigmentation. But it can cause mottled hypopigmentation. The LFQS had obvious lesion clearance after the fourth treatment.

Для цитирования: Cen Qingqing, Zhu Jiafang, Zhou Lucia, Yu Wenxin, Wu Xianglei, Liu Ying, Ma Gang, Luo Lan, Lin Xiaoxi. Comparison of the safety and efficacy of low fluence Q-switched 1064-nm and conventional Q-Switched 755-nm lasers in the treatment of café-au-lait macules: A prospective self-controlled trial.. Lasers in surgery and medicine. 2022. DOI: 10.1002/lsm.23594.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.