MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-88588-y

Медицинская библиотека · Scientific reports · 2025

Comparison of monovision surgery using ICL V4c or femtosecond laser LASIK for myopia correction in the presbyopia age patients.

Ye Yuhao, Xian Yiyong, Liu Fang, Zhang Zhe, Niu Lingling, Shi Wanru, Wang Xiaoying, Zhou Xingtao, Zhao Jing

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

To compare the long-term outcomes of monovision surgery using implantable collamer lens (ICL) V4c and femtosecond laser-assisted in situ keratomileusis (FS-LASIK) in myopic patients with early presbyopia. This case series study included 48 eyes of 24 patients (male/female: 10/14, mean age 45.50 ± 3.82 years) and followed-up for 4.5 years (54.00 ± 9.77 months). Patients were examined for spherical equivalent, uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure, presbyopic add power, visual acuity (VA) (logMAR) of dominant eyes (D-eye), non-dominant eyes (nD-eye), and both eyes (Bi) at 0.4 m, 0.8 m, and 5 m, corneal wavefront aberration, and contrast sensitivity (CS). All surgeries were uneventful. The safety indices of ICL V4c group and FS-LASIK group were 1.17 ± 0.30 and 0.98 ± 0.20 (p < 0.05), and the efficacy indices were 0.79 ± 0.07 and 0.52 ± 0.07 (p < 0.05) respectively. The binocular VA (logMAR) of ICL V4c group and FS-LASIK group at 5.0 m were: 0.02 ± 0.11, 0.18 ± 0.30; 0.8 m: 0.09 ± 0.12, - 0.01 ± 0.11; 0.4 m: - 0.02 ± 0.06, - 0.03 ± 0.08, (p > 0.05 at three distances). Compared with ICL V4c group, lower CS was observed at 1.0 cpd in the FS-LASIK group (1.07 ± 0.31 vs. 0.80 ± 0.51, p = 0.043). Monovision surgery using ICL V4c and FS-LASIK provides good binocular visual acuity at near-to-far distances in myopia patients in the presbyopia age group.

Для цитирования: Ye Yuhao, Xian Yiyong, Liu Fang, Zhang Zhe, Niu Lingling, Shi Wanru, Wang Xiaoying, Zhou Xingtao, Zhao Jing. Comparison of monovision surgery using ICL V4c or femtosecond laser LASIK for myopia correction in the presbyopia age patients.. Scientific reports. 2025. DOI: 10.1038/s41598-025-88588-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.