MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-026-04232-2

Медицинская библиотека · International ophthalmology · 2026

Evaluation of a cornea-specialized large language model for diagnostic and management accuracy in complex corneal cases.

Mikhail David, Milad Daniel, Antaki Fares, Milad Jason, Sedarous Fady, Martin Rachel Ann, Vaudoisey Louis, El-Khoury Jonathan, Jabbour Samir, Duval Renaud, Harissi-Dagher Mona

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate whether a cornea-specialized large language model (LLM) enhanced with retrieval-augmented generation (RAG) improves clinicians' diagnostic and management accuracy in complex corneal cases compared to a general-purpose GPT-4o model and unaided clinician performance.

METHODS

This prospective, randomized, masked evaluation study involved three cornea trainees who each independently reviewed 39 real-world corneal cases under three experimental conditions: unaided, GPT-4o-assisted, and assisted by a cornea-specialized GPT-4o model. The cornea-specialized model was constructed by embedding over 200 publicly available Wikipedia articles into GPT-4o's RAG framework. Participants provided open-ended diagnoses and selected the next-step management options (multiple choice). They were allowed up to three GPT-4o queries per case, and the AI-assisted arms were randomized to minimize bias. Accuracy for both tasks was compared against expert reference standards using McNemar's test.

RESULTS

Diagnostic accuracy was 48.7%, 20.5%, and 38.5% unaided, improving to 69.2%, 46.2%, and 59.0% with general GPT-4o (p<0.04). The cornea-specialized GPT-4o further improved accuracy to 71.8%, 48.7%, and 74.4%, with improvements over unaided performance for all clinicians (p<0.01). For next-step decisions, unaided accuracy was 76.9%, 87.2%, and 59.0%. With the specialized model, Ophthalmologist 3 improved to 71.8% (p<0.05), Ophthalmologist 1 remained high at 82.1%, and Ophthalmologist 2 declined to 64.1% (p<0.05).

CONCLUSIONS

A cornea-specialized LLM enhanced with RAG improved diagnostic accuracy in complex corneal cases, particularly among clinicians with lower baseline performance. Effects on management accuracy were inconsistent. Future studies should explore the use of open-ended management tasks and examine whether smaller, curated retrieval corpora yield better model performance.

Для цитирования: Mikhail David, Milad Daniel, Antaki Fares, Milad Jason, Sedarous Fady, Martin Rachel Ann, Vaudoisey Louis, El-Khoury Jonathan, Jabbour Samir, Duval Renaud, Harissi-Dagher Mona. Evaluation of a cornea-specialized large language model for diagnostic and management accuracy in complex corneal cases.. International ophthalmology. 2026. DOI: 10.1007/s10792-026-04232-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.