MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.12707

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2015

High Incidence of Low Catheter-Tissue Contact Force at the Cavotricuspid Isthmus During Catheter Ablation of Atrial Flutter: Implications for Achieving Isthmus Block.

Kumar Saurabh, Morton Joseph B, Lee Geoffrey, Halloran Karen, Kistler Peter M, Kalman Jonathan M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Recurrent atrial flutter following cavotricuspid isthmus (CTI) ablation remains a significant problem. The prevalence of low contact force (CF) during CTI ablation using standard tools is unknown. Our aim was to characterize the prevalence of low CF applications when experienced operators performed CTI ablation using "traditional" markers of contact blinded to CF measurements.

METHODS AND

RESULTS

Average CF (grams, g) and force-time integral (FTI) was analyzed in 458 lesions in 17 patients undergoing CTI ablation. The isthmus was divided into the annular, mid and caval segments for region-specific analysis. Despite "good" contact using traditional markers, there was significant variability in CF within each isthmus segment (e.g., annular CTI 1-57 g). A high proportion of lesions had a CF <10 g (40%). Lowest CF was the annular (median 9 g), followed by the mid (12 g) and the caval CTI (18 g, P < 0.001). Sites of acute CTI re-connection had a lower average CF and FTI than nonreconnected sites (P < 0.05). Each 1 g increase in CF was associated with a 16% reduction in risk of recovered CTI conduction (95% confidence interval: 4-27%, P = 0.01).

CONCLUSION

Use of surrogate markers of "good contact" during ablation by experienced operators in the absence of real-time CF sensing resulted in nearly half of all lesions being delivered with low CF with marked region-specific variability in CF. Low CF was implicated in longer time to achieve conduction block and increased risk of acute reconnection. These findings underscore the importance of real-time CF measurements for optimizing ablation of typical atrial flutter.

Для цитирования: Kumar Saurabh, Morton Joseph B, Lee Geoffrey, Halloran Karen, Kistler Peter M, Kalman Jonathan M. High Incidence of Low Catheter-Tissue Contact Force at the Cavotricuspid Isthmus During Catheter Ablation of Atrial Flutter: Implications for Achieving Isthmus Block.. Journal of cardiovascular electrophysiology. 2015. DOI: 10.1111/jce.12707.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.