MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archopht.123.11.1532

Медицинская библиотека · Archives of ophthalmology (Chicago, Ill. : 1960) · 2005

Clinical comparison of contour and applanation tonometry and their relationship to pachymetry.

Kniestedt Christoph, Lin Shan, Choe Joyce, Bostrom Alan, Nee Michelle, Stamper Robert L

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To compare intraocular pressure readings of recently introduced dynamic contour tonometry (DCT) with pneumatonometry (PTG) and Goldmann applanation tonometry (GAT) and to correlate central corneal thickness (CCT) with these readings.

DESIGN

Prospective, cross-sectional observation and instrument validation study. We included 258 independent eyes with normal anterior segment examinations results, irrespective of glaucoma diagnosis or glaucoma suspect. After pachymetry, DCT, PTG, and GAT were performed in a randomized order. Intraocular pressures as measured by DCT, PTG, and GAT were compared with each other and with CCT.

RESULTS

Eyes with thinner CCTs tended to yield lower intraocular pressure measurements by GAT. A significant correlation (Pearson product moment correlation, P<.001) between CCT and GAT was found with a regression of 0.25 mm Hg per 10 microm (R2 = 0.060). Variation of CCT had no significant effect on intraocular pressure measurements by PTG (P = .10; R2 = 0.01) and DCT (P = .80; R2<0.01). A piecewise regression model showed that GAT readings are not linearly correlated with CCT. Comparison of the slopes below and above 535 microm showed the highest significance (P<.001).

CONCLUSIONS

Goldmann applanation tonometry readings are potentially influenced by CCT, whereas PTG and DCT seem to be less dependent on CCT. Correlation between CCT and GAT is not linear. A simple correction formula suggesting a linear relationship might not be correct.

Для цитирования: Kniestedt Christoph, Lin Shan, Choe Joyce, Bostrom Alan, Nee Michelle, Stamper Robert L. Clinical comparison of contour and applanation tonometry and their relationship to pachymetry.. Archives of ophthalmology (Chicago, Ill. : 1960). 2005. DOI: 10.1001/archopht.123.11.1532.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.