Prognostic Value of a Coronary Computed Tomography Angiography-Derived Ischemia Algorithm: Comparison Against Hybrid Coronary Computed Tomography Angiography/Positron Emission Tomography Imaging.
Аннотация
BACKGROUND
Artificial intelligence-guided quantitative computed tomography ischemia (AI-QCTischemia) is a novel machine-learning method for predicting myocardial ischemia from coronary computed tomography angiography (CCTA). This observational cohort study aimed to compare the long-term prognostic value of AI-QCTischemia with hybrid CCTA/positron emission tomography (PET) myocardial perfusion imaging in suspected coronary artery disease (CAD).
METHODS
Symptomatic patients with suspected CAD underwent CCTA with selective downstream PET to detect ischemic CAD. Blinded reanalysis of CCTA images was done using the AI-QCTischemia algorithm, providing a binary result (normal versus abnormal).
RESULTS
In the full analysis set (n=2271), hybrid CCTA/PET imaging was successful in 94% of the patients and AI-QCTischemia evaluation was feasible in 83%, resulting in a per-protocol set of 1772 patients (19% with ischemic CAD on hybrid CCTA/PET and 25% with abnormal AI-QCTischemia). There was moderate-to-substantial agreement between the methods (Cohen's κ=0.61). During a median follow-up of 7.0 years, 177 (10%) patients experienced the composite end point of all-cause death, myocardial infarction, or unstable angina. Ischemic CAD on hybrid CCTA/PET was predictive of the composite end point (hazard ratio [HR], 2.35 [95% CI, 1.62-3.40]; P<0.001), after adjustment for clinical variables and early (6-month) myocardial revascularization. Similarly, an abnormal (ischemic) AI-QCTischemia result was independently predictive of adverse outcomes (adjusted HR, 1.98 [95% CI, 1.39-2.80]; P<0.001). The adjusted models, including either hybrid CCTA/PET or AI-QCTischemia, demonstrated similar discriminative ability (C-index 0.734 versus 0.729; P=0.53).
CONCLUSIONS
The AI-QCTischemia algorithm demonstrated long-term prognostic value comparable to hybrid CCTA/PET perfusion imaging in suspected CAD.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.