American journal of ophthalmology · 2011
23-Gauge transconjunctival pars plana vitrectomy for removal of retained lens fragments.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Baker Paul S, Spirn Marc J, Chiang Allen, Regillo Carl D, Ho Allen C, Vander James F, Kaiser Richard S
Аннотация
PURPOSE: To examine the usefulness of 23-gauge pars plana vitrectomy (PPV) in removing retained lens fragments and to determine which cases require 20-gauge ultrasonic fragmentation.
DESIGN: Retrospective comparative case series.
METHODS: Twenty eyes in 20 consecutive patients who had 23-gauge PPV for retained lens fragments after complicated cataract surgery at Wills Eye Institute were retrospectively reviewed. Retained lens fragments were graded based on percentage of total nuclear size. Every surgical case started with 23-gauge PPV, but 1 sclerotomy was enlarged to facilitate 20-gauge ultrasonic fragmentation if all lens material could not be adequately removed.
RESULTS: Twelve patients (60%) were successfully managed with 23-gauge PPV alone while 8 patients (40%) required 20-gauge ultrasonic fragmentation. The 23-gauge cases had a lower percentage of retained lens fragments (median 10%, range 0% to 75%) compared to the 20-gauge cases (median 90%, range 10% to 100%).
CONCLUSION: 23-Gauge PPV is a feasible approach in the surgical management of select cases of retained lens fragments.
DESIGN: Retrospective comparative case series.
METHODS: Twenty eyes in 20 consecutive patients who had 23-gauge PPV for retained lens fragments after complicated cataract surgery at Wills Eye Institute were retrospectively reviewed. Retained lens fragments were graded based on percentage of total nuclear size. Every surgical case started with 23-gauge PPV, but 1 sclerotomy was enlarged to facilitate 20-gauge ultrasonic fragmentation if all lens material could not be adequately removed.
RESULTS: Twelve patients (60%) were successfully managed with 23-gauge PPV alone while 8 patients (40%) required 20-gauge ultrasonic fragmentation. The 23-gauge cases had a lower percentage of retained lens fragments (median 10%, range 0% to 75%) compared to the 20-gauge cases (median 90%, range 10% to 100%).
CONCLUSION: 23-Gauge PPV is a feasible approach in the surgical management of select cases of retained lens fragments.