MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0040-1720988

Медицинская библиотека · Journal of neurological surgery. Part A, Central European neurosurgery · 2020

The Use of Real-Time 3D Intraoperative Ultrasound "Angiography" in Localization and Occlusion Control of a Ruptured Mycotic Aneurysm: A Case Report.

Nerntengian Ntenis, Gkasdaris Grigorios, Barettas Nikolaos, Theodoropoulou Efthymia, Birbilis Theodosios

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Infectious (mycotic) aneurysms are rare with high mortality and are most commonly found at the distal branches of the middle cerebral artery (MCA). Because aneurysms of the distal MCA are located deep in the Sylvian fissure and are small in size, intraoperative identification and safe clip occlusion of these aneurysms are challenging. Thus, the use of intraoperative imaging and navigation can be beneficial. We describe the use of intraoperative real-time 3D ultrasound "angiography" (3D-iUS) in localizing and occlusion control of a ruptured MCA M3 segment mycotic aneurysm. To our knowledge, its application in the surgery of a ruptured mycotic distal MCA aneurysm is not yet reported.

CLINICAL PRESENTATION: A 54-year-old woman with a history of septic thrombophlebitis treated with long-term antibiotic therapy presented with sudden onset of headaches, dysphasia, and seizures. Computed tomography (CT) revealed subarachnoid hemorrhage in the distal portion of the left Sylvian fissure. Digital subtraction angiography (DSA) showed an aneurysm at the peripheral branch of the M3 segment of the MCA with characteristics of an infectious aneurysm. A microsurgical treatment was decided. 3D-iUS scan showed an aneurysm within the Sylvian fissure at a depth of 5 cm. The aneurysm was clipped and a repeated 3D-iUS scan showed total occlusion of the aneurysm and patency of the parent artery. The intraoperative findings were confirmed with a postoperative DSA.

CONCLUSION

Our case report shows that real-time 3D-iUS, despite its limitations, is an important tool to locate and ascertain the successful clip occlusion of an aneurysm, especially when intraoperative angiography (IA) and indocyanine green (ICG) videoangiography are not available due to low-income settings.

Для цитирования: Nerntengian Ntenis, Gkasdaris Grigorios, Barettas Nikolaos, Theodoropoulou Efthymia, Birbilis Theodosios. The Use of Real-Time 3D Intraoperative Ultrasound "Angiography" in Localization and Occlusion Control of a Ruptured Mycotic Aneurysm: A Case Report.. Journal of neurological surgery. Part A, Central European neurosurgery. 2020. DOI: 10.1055/s-0040-1720988.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.