m+Medelevator.RU
← Поиск публикаций
International ophthalmology · 2026

Comparative analysis of 70 SMILE and 70 toric ICL eyes for myopic oblique astigmatism: a matched cohort study from an initial pool of 11,929 eyes.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Assaf Abdelrahman, Alsaify Baha A, Troeber Leonie, Javadi Amir, Wiltfang Rainer, Bechmann Martin, Becker Klio, Feucht Nikolaus

Аннотация

PURPOSE: To compare visual, refractive, and vector-based astigmatic outcomes between Small Incision Lenticule Extraction (SMILE) and toric Implantable Collamer Lens (ICL) implantation in patients with myopic oblique astigmatism.

METHODS: In this retrospective, matched cohort study, 140 eyes (70 SMILE, 70 toric ICL) with oblique astigmatism were treated at a single center. Groups were matched preoperatively for refractive cylinder and spherical equivalent within ± 0.50 D. Postoperative outcomes at six weeks were assessed, including uncorrected and corrected distance visual acuity (UDVA, CDVA), spherical equivalent (SEQ), astigmatism correction using vector analysis (Alpins method), and safety and efficacy indices. A post hoc power analysis was performed for the astigmatic correction index.

RESULTS: The efficacy index was 0.97 ± 0.17 in the ICL group and 0.94 ± 0.15 in the SMILE group. The safety index was 1.02 ± 0.11 (ICL) versus 1.01 ± 0.09 (SMILE). UDVA equal to or better than preoperative CDVA was achieved in 83% of ICL eyes and 79% of SMILE eyes. SEQ within ± 0.50 D was observed in 85.7% (ICL) versus 81.4% (SMILE). The astigmatic correction index was 0.97 for ICL and 1.04 for SMILE. Linear regression showed stronger correlation between target and achieved astigmatism in the ICL group (slope = 1.04, R2 = 0.77) compared to SMILE (slope = 0.76, R2 = 0.67). Power analysis confirmed 80.5% power to detect clinically meaningful differences.

CONCLUSIONS: Both SMILE and toric ICL are effective and safe for correcting myopic oblique astigmatism. However, toric ICL demonstrated slightly greater precision in axis alignment and refractive predictability, supporting its use in cases of high oblique astigmatism where rotational accuracy is critical.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты