Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmias.

Christoph Marian, Wunderlich Carsten, Moebius Stefanie, Forkmann Mathias, Sitzy Judith, Salmas Jozef, Mayer Julia, Huo Yan, Piorkowski Christopher, Gaspar Thomas

Clinical StudyСтатьяПеревод в очереди

Аннотация

AIMS: Despite the use of established 3D-mapping systems, invasive electrophysiological studies and catheter ablation require high radiation exposure of patients and medical staff. This study investigated whether electroanatomic catheter tracking in prerecorded X-ray images on top of an existing 3D-mapping system has any impact on radiation exposure.

METHODS AND

RESULTS

Two hundred and ninety-five consecutive patients were either ablated with the guidance of the traditional CARTO-3 system (c3) or with help of the CARTO-UNIVU system (cU): [typical atrial flutter (AFL) n = 58, drug refractory atrial fibrillation (AF) n = 81, ectopic atrial tachycardia (EAT) n = 37, accessory pathways (APs) n = 22, symptomatic, idiopathic premature ventricular complexes (PVCs) n = 56, ventricular tachycardias (VTs) n = 41]. The CARTO-UNIVU allowed a reduction in radiation exposure: fluoroscopy time: AFL c3: 8.6 ± 0.8 min vs. cU: 2.9 ± 0.3 min, P < 0.001; AF c3: 16.0 ± 1.3 min vs. cU: 6.4 ± 0.9 min, P < 0.001; EAT c3: 23.4 ± 3.1 min vs. cU: 9.7 ± 1.7 min, P < 0.001; AP c3: 7.1 ± 1.2 min vs. cU: 6.0 ± 1.5 min, P = 0.59; PVCs c3: 17.6 ± 2.3 min vs. cU: 15.2 ± 2.8 min, P = 0.52; VT c3: 31.4 ± 3.4 min vs. cU: 17.5 ± 2.4 min, P = 0.003. Corresponding to the fluoroscopy time the fluoroscopy dose was also reduced significantly. These advantages were not at the cost of increased procedure times, periprocedural complications, or decreased acute ablation success rates.

CONCLUSION

In a wide spectrum of cardiac arrhythmias, and especially in AF and VT ablation, fluoroscopy integrated 3D mapping contributed to a dramatic reduction in radiation exposure without prolonging procedure times and compromising patient's safety. That effect, however, could not be maintained in patients with APs and PVCs.

Для цитирования: Christoph Marian, Wunderlich Carsten, Moebius Stefanie, Forkmann Mathias, Sitzy Judith, Salmas Jozef, Mayer Julia, Huo Yan, Piorkowski Christopher, Gaspar Thomas. Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmias.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2015. DOI: 10.1093/europace/euu334.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.