MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.repc.2014.05.003

Медицинская библиотека · Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology · 2014

Remote magnetic navigation for ablation of typical atrial flutter: Long-term results.

Parreira Leonor, Cavaco Diogo, Carmo Pedro, Reis-Santos Katya, Quaresma Rita, Teixeira Tiago, Marques Marta, Adragão Pedro

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION AND AIM: Remote magnetic navigation has proved to be effective in the ablation of most supraventricular and ventricular arrhythmias. Initial studies reported worse results with this system compared to conventional ablation for atrial flutter. The aim of this study was to assess the acute and long-term success of atrial flutter ablation with remote magnetic navigation and to retrospectively compare the results obtained with an 8-mm tip catheter versus an irrigated catheter.

METHODS

We studied 38 consecutive patients, mean age 61 ± 15 years, 28 male, who underwent ablation of typical atrial flutter with the Niobe II remote magnetic navigation system (Stereotaxis). Ablation was performed with an 8-mm tip catheter in 17 patients and with an irrigated-tip catheter in 21 patients. Acute success was defined as the presence of bidirectional isthmus block, and long-term success as absence of symptoms and atrial flutter during Holter monitoring.

RESULTS

Bidirectional isthmus block was achieved in 37 patients (97%), and the success rate was similar in both groups. Total procedure time was not significantly different between the groups but fluoroscopy time was shorter in the irrigated tip group (13.4 ± 3.7 min vs. 6 ± 4.4 min; p<0.01). The number of applications and total radiofrequency time did not differ. There were no complications. During a follow-up of 32 ± 19 months there were two relapses, one in each group.

CONCLUSIONS

The Niobe II remote control system for ablation of typical atrial flutter is safe and effective in both the short and long term. The 8-mm and irrigated-tip catheters showed similar safety and efficacy.

Для цитирования: Parreira Leonor, Cavaco Diogo, Carmo Pedro, Reis-Santos Katya, Quaresma Rita, Teixeira Tiago, Marques Marta, Adragão Pedro. Remote magnetic navigation for ablation of typical atrial flutter: Long-term results.. Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology. 2014. DOI: 10.1016/j.repc.2014.05.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.