Leal João Carlos, Gregori Francisco, Galina Luis Eduardo, Thevenard Rubens S, Braile Domingo Marcolino

Аннотация

OBJECTIVE: The objective of this study was to evaluate, using echocardiography, the functioning of the mitral valve apparatus in patients submitted to standardized bovine pericardium chordae implantation to substitute ruptured chordae tendineae or elongated chordae with a significant degree of thinning.

METHOD: Standardized bovine pericardium chordae were implanted in 23 patients with mitral valve insufficiency due to ruptured or elongated chordae with significant thinning. The ages of the patients varied from 23 to 84 years old (mean 62 years old). The most common cause was fibroelastic degeneration affecting 20 (87.0%) patients. The standardized bovine pericardium chordae were manufactured in sets connected at both ends by two polyester-reinforced rods thereby forming a single block. The bovine pericardium chordae measure 2 mm wide with 3 mm between the chordae. The sets of bovine pericardium chordae are produced in lengths varying from 20 to 35 mm. In 17 (73.9%) patients bovine pericardium chordae were implanted in the posterior cusp and in 6 (26.1%) in the anterior cusp. All the patients were evaluated in the postoperative period by echocardiography after a mean follow-up of six months.

RESULTS: The echocardiography in the postoperative period demonstrated an absence of reflux in 11 (47.8%) patients, slight reflux in 8 (34.8%) and slight to moderate reflux in 3 (13.0%). The opening and mobility of the mitral valve was normal in the 22 surviving patients.

CONCLUSION: The echocardiography demonstrated good functioning of the mitral valve apparatus in patients submitted to the implantation of standardized bovine pericardium chordae to substitute ruptured chordae tendineae or elongated chordae with a significant degree of thinning.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049