MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo.2009.171009

Медицинская библиотека · The British journal of ophthalmology · 2010

Presence of free radicals in intracameral agents commonly used during cataract surgery.

Lockington David, Macdonald Elisabeth C A, Young David, Stewart Philip, Caslake Muriel, Ramaesh Kanna

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Free radicals are known to cause cellular damage and are present in ophthalmic preparations. Corneal defence mechanisms are bypassed in intra-ocular surgery. We evaluated commonly used intracameral agents to ascertain the presence of free radicals and investigate the possibility of anterior segment and endothelial toxicity.

METHODS

Samples of 19 commonly used intracameral preparations were analysed for total free radical presence on an Instrument Laboratory IL600 using a Randox Kit for Total Antioxidant Status (RANDOX Laboratories Ltd, Crumlin, UK).

RESULTS

Free radical concentrations for the 19 intracameral agents ranged from 0 to 3.59 mmol/l, with median value of 0.34 mmol/l (mean value 0.933±1.19 mmol/l). Phenylephrine had the highest presence of free radicals, which were considerably higher than those for 0.5% hydrogen peroxide at all tested dilutions. Other notable results included cefuroxime (0.61 mmol/l), 2% undiluted lidocaine (0.34 mmol/l) and bevacizumab (0.59 mmol/l).

CONCLUSION

The results indicate that free radicals are present in intracameral surgical agents and some are in the order of 0.5% hydrogen peroxide. The risks of endothelial damage must be considered when using multiple intracameral preparations in complicated cataract surgery. Free radicals in intracameral preparations may be a contributing cause in cases of toxic anterior segment syndrome.

Для цитирования: Lockington David, Macdonald Elisabeth C A, Young David, Stewart Philip, Caslake Muriel, Ramaesh Kanna. Presence of free radicals in intracameral agents commonly used during cataract surgery.. The British journal of ophthalmology. 2010. DOI: 10.1136/bjo.2009.171009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.