Measurement of Aniseikonia Tolerance in Binocular Fusion.

Hoshikawa Rie, Handa Tomoya, Akaishizawa Chiho, Shoji Nobuyuki

СтатьяОтозванная публикацияПеревод в очереди
Источник пометил публикацию как отозванную.

Аннотация

SIGNIFICANCE: The determination of aniseikonia tolerance may aid in developing optimal treatment plans for cataract surgery, refractive surgery, and refractive correction with glasses and contact lenses.

PURPOSE: This study aimed to measure aniseikonia tolerance.

METHODS

We included 33 patients (mean age ± standard deviation, 28.9 ± 6.4 years; male/female, 12:21) with anisometropia ≤1.0 D and best spectacle-corrected visual acuity of 20/20 or more in both eyes, with no ophthalmologic disease other than refractive errors and no history of ocular surgery. The exclusion criteria were anisometropia >1.0 D, axial length difference >0.5 mm, corneal refractive power difference >0.5 D, astigmatism >3.0 D, stereoacuity threshold >100 arcsec according to the Titmus Stereo Test, and >0% aniseikonia according to the New Aniseikonia Test. Aniseikonia tolerance was assessed using Eyemark Hello, a haploscope using gaze detection technology. Although the optotype of one eye was enlarged or reduced at a speed of 2%/s, the patients were instructed to press a button on the controller to indicate blurring, flickering, and diplopia. The value at which the patient responded was considered the aniseikonia tolerance value and assessed thrice per eye, five times if the values were highly variable, and then averaged.

RESULTS

The mean aniseikonia tolerance was approximately 3%; the median value was approximately 2% (range, 1.0 to 11.5%; dominant eye, 3.3 ± 2.6%; nondominant eye, 2.9 ± 1.8%). No significant difference in aniseikonia tolerance between the dominant and nondominant eyes was observed for the enlarged optotypes. No case showed changes in the ocular alignment before discomfort occurred. No significant correlation was observed between aniseikonia tolerance and anisometropia, axial length difference, corneal power difference, and ocular deviation.

CONCLUSIONS

Aniseikonia should be maintained at <2% for a comfortable visual environment. Aniseikonia tolerance may be an important indicator for cataract surgery, refractive surgery, and spectacle correction.

Для цитирования: Hoshikawa Rie, Handa Tomoya, Akaishizawa Chiho, Shoji Nobuyuki. Measurement of Aniseikonia Tolerance in Binocular Fusion.. Optometry and vision science : official publication of the American Academy of Optometry. 2023. DOI: 10.1097/opx.0000000000001990.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.