m+Medelevator.RU
← Поиск публикаций
Translational vision science & technology · 2026

BlinkNet-Q: A Deep Learning-Based Software for Real-Time Blink Rate Quantification and Incomplete-Blink Pattern Recognition.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xu Zhiqiang, Shen Jiahui, Liu Anran, Wen Jun, Li Hongwen, Arriola-Villalobos Pedro, Wu Minhui, Qu Jia, Lu Fan, Hu Liang

Аннотация

PURPOSE: To develop and validate a dual deep learning model (DLM)-based software (BlinkNet-Q) for near real-time quantification of blink rate and incomplete blinks using standard red-green-blue video.

METHODS: BlinkNet-Q integrated two DLMs: DLM-1 classified open-eye versus complete-blink frames, and DLM-2 differentiated complete from incomplete blinks. This proof-of-concept technical validation study included separate model development and independent testing cohorts. The development cohort comprised 15 participants (30 eyes), yielding 2953 annotated frames for training and internal validation, with participant-level data splitting. The testing cohort included 39 participants (39 eyes) and was used for final evaluation of the BlinkNet-Q. Frame-wise analysis with computer vision-based eye localization enabled automated blink quantification. Performance was assessed using classification metrics, regression-based metrics, intraclass correlation coefficient (ICC), and Bland-Altman analysis.

RESULTS: DLM-1 achieved an area under the curve (AUC) of 0.989 (95% confidence interval [CI], 0.932-0.993), and DLM-2 reached an AUC of 0.884 (95% CI, 0.854-0.963). The BlinkNet-Q showed strong agreement with manual counting for blink rate (ICC = 0.973; R² = 0.948; mean absolute error [MAE] = 1.262 blinks/min) and incomplete-blink ratio (ICC = 0.937; R² = 0.876; MAE = 0.059), with small mean biases under standardized recording conditions.

CONCLUSIONS: BlinkNet-Q demonstrated the technical feasibility of automated blink rate and incomplete-blink quantification under standardized recording conditions, supporting its potential as a software prototype for blink assessment. Further external validation in diverse clinical populations is needed before clinical implementation.

TRANSLATIONAL RELEVANCE: BlinkNet-Q may support future development of accessible, camera-based blink assessment tools for ocular surface evaluation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты