A Genetic Lab-on-Phone Test for Point-of-Care Diagnostic of Lactose Intolerance near Patient and in less than 90 Minutes.
Аннотация
BACKGROUND
The -13910 C/T single nucleotide polymorphism located within the MCM6 gene, an enhancer region located upstream of the lactase-phlorizin hydrolase gene, is associated with lactase persistence/non-persistence traits among the Caucasian population. The performance of a new point-of-care CE-IVD (In Vitro Diagnostic) marked isothermal lab-on-phone lactose intolerance assay, using crude samples, was assessed in comparison with Sanger sequencing using purified DNA, as reference method.
METHODS
The study was conducted following a non-probability sampling using direct buccal swab (n = 63) and capillary blood (n = 43) clinical samples from a total of 63 volunteers. A 3 × 3 confusion matrix/contingency table was used to evaluate the performance of the isothermal lab-on-phone lactose intolerance assay.
RESULTS
The isothermal lab-on-phone lactose intolerance assay successfully detected the -13910 C/T variant with a limit of detection of 5 cells/assay and demonstrated an overall accuracy of 98.41% (95% CI, 91.47%-99.96%) for buccal swab samples and 100% (95% CI, 91.19%-100%) for capillary blood, taking just 90 min from sample to result, with only 2 min hands-on.
CONCLUSIONS
The lab-on-phone pocket-sized assay displayed good performance when using direct buccal swab and capillary blood samples, enabling a low-cost, real-time, and accurate genotyping of the -13910 C/T region for the rapid diagnosis of primary lactose intolerance at point-of-care, which enables a prompt implementation of appropriate diet habits and/or intolerance therapies. To our knowledge, this is the first point-of-care genetic test for lactose intolerance to be made available on the market.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.