MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1600-0536.2010.01797.x

Медицинская библиотека · Contact dermatitis · 2010

Comparison of three different techniques for application of water solutions to Finn Chambers®.

Frick-Engfeldt Malin, Gruvberger Birgitta, Isaksson Marléne, Hauksson Inese, Pontén Ann, Bruze Magnus

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

With regard to contact allergy, the dose of a sensitizer per unit skin area is an important factor for both sensitization and elicitation, and therefore a known amount/volume of test preparation should be applied at patch testing.

OBJECTIVES

To compare three different techniques for the application of aqueous solutions to Finn Chambers, in order to determine the precision and accuracy of each technique when the recommended 15 µl volume is applied.

METHODS

Four technicians applied formaldehyde 1.0% aq. (wt/vol) and methylchloroisothiazolinone/methylisothiazolinone 200 ppm (wt/vol) in sets of 10 onto Finn Chambers, with three different techniques: (i) micro-pipetting; (ii) dripping the solutions; and (iii) dripping the solutions followed by removal of excess solution with a soft tissue. Assessment of the variations was performed with the use of descriptive data. The ability to apply the exact amount was assessed by Fisher's exact test by categorizing each application as in or out of the range 12-18 µl.

RESULTS/

CONCLUSIONS

The micro-pipette technique had the best accuracy and precision, as well as the lowest inter-individual variation. The technique in which excess solution was removed had good precision, but failed in the application of the defined amount, i.e. 15 µl.

Для цитирования: Frick-Engfeldt Malin, Gruvberger Birgitta, Isaksson Marléne, Hauksson Inese, Pontén Ann, Bruze Magnus. Comparison of three different techniques for application of water solutions to Finn Chambers®.. Contact dermatitis. 2010. DOI: 10.1111/j.1600-0536.2010.01797.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.