DOI 10.1097/rli.0000000000001248
Per-Lesion Assessment of Individual MRI Sequences and 68 Ga-DOTATATE PET in Neuroendocrine Liver Metastases.
Аннотация
OBJECTIVES
To explore magnetic resonance imaging (MRI) and gallium-68 ( 68 Ga)-DOTATATE positron emission tomography (PET) performance in the assessment of neuroendocrine liver metastases (NELMs) on a per-lesion basis, with particular attention to the contribution of individual MRI sequences and assessment of other factors that might influence their detection.
MATERIALS AND
METHODS
This observational retrospective study included patients with histologically confirmed neuroendocrine tumors who underwent both contrast-enhanced MRI and 68 Ga-DOTATATE PET within 12 weeks between August 2017 and December 2023. Three readers in consensus assessed individual MRI sequences [diffusion-weighted imaging (DWI), dynamic contrast-enhanced imaging (DCE), and hepatobiliary phase (HBP) imaging when available], entire MRI data set, and PET in random order. The reference standard was histopathology or follow-up imaging. Diagnostic performance metrics were calculated using generalized estimating equations with Bonferroni correction. Correlations were assessed using Pearson correlation coefficients.
RESULTS
A total of 1249 lesions, comprising 1050 metastases, were analyzed in 60 patients (mean age: 64.9±11.5 years; 56.7% male). Compared with PET, MRI demonstrated superior sensitivity (93% vs. 59%, P <0.001) and accuracy (93% vs. 63%, P <0.001), with DWI and HBP providing the highest sensitivity (89% and 92%). Size-stratified analysis showed that MRI outperformed PET, particularly for metastases <5 mm (81.6% vs. 19.7%) and 5 to 10 mm (96.1% vs. 61.8%) ( P <0.001). Arterial enhancement and portal venous washout were present in 67.8% and 23.7% of metastases, respectively, with only portal venous washout showing size dependence (11.9% in <5 mm to 55.6% in >20 mm lesions, P <0.01). PET-negative metastases were smaller than PET-positives (5.0 vs. 8.0 mm, P =0.001), with lesion size correlating with maximum standardized uptake values and normalized uptake ratios ( r =0.54 to 0.59, P <0.001).
CONCLUSIONS
MRI outperformed 68 Ga-DOTATATE PET in detecting NELMs, with DWI and HBP providing particularly high sensitivity for small metastases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.