MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jss.2025.09.068

Медицинская библиотека · The Journal of surgical research · 2025

Facilitating In-Stent Restenosis Research: A Novel Removable Stent Strut Model in Mice.

Zhou Yang, Shu Chang, He Hao, Wang Tun, Li Quanming

СтатьяВалидационное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

In-stent restenosis (ISR) remains a clinical challenge. Existing mouse models are technically demanding and limit detailed analysis. This study aimed to develop and validate a simplified mouse ISR model mimicking stent biomechanics while allowing easy stent strut removal for comprehensive tissue analysis.

MATERIALS AND

METHODS

Nitinol stent struts were implanted into the infrarenal abdominal aorta of C57BL/6J mice and secured with sutures (stent strut group). A suture-only control group underwent the same surgery without strut implantation. Mice were harvested at 2 and 4 wk. Stent struts were easily removed after freezing. Histological (hematoxylin and eosin , Masson's trichrome) and immunofluorescence (Mac-2, α smooth muscle actin) analyses assessed neointimal hyperplasia, collagen, and cell composition.

RESULTS

The stent strut implantation model showed high surgical success. Histological analysis in the stent strut group revealed progressive neointimal hyperplasia, with significantly increased neointimal thickness and collagen at 4 versus 2 wk. The suture-only group exhibited negligible neointimal formation, confirming the strut primarily induced neointima. Immunofluorescence of stented segments showed decreased macrophages (Mac-2) and increased smooth muscle (smooth muscle actin [α-SMA]) cells at 4 wk.

CONCLUSIONS

This novel mouse ISR model recapitulates key human ISR features, offering a simplified, reproducible platform. Easy stent strut removal is a significant advantage. The suture-only control validates that neointimal formation is a specific response to the strut. This model is valuable for investigating ISR mechanisms and novel therapies.

Для цитирования: Zhou Yang, Shu Chang, He Hao, Wang Tun, Li Quanming. Facilitating In-Stent Restenosis Research: A Novel Removable Stent Strut Model in Mice.. The Journal of surgical research. 2025. DOI: 10.1016/j.jss.2025.09.068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.