MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.redar.2012.04.017

Медицинская библиотека · Revista espanola de anestesiologia y reanimacion · 2012

[The finding of glucose in the fluid obtained by epidural catheter after its insertion during combined intradural-epidural anaesthesia with hyperbaric bupivacaine is a usual occurrence].

Sánchez Morillo J, Estruch Pérez M J, Balaguer Doménech J, Gallen Martín L, Hernández Cádiz M J, Solaz Roldán C

Аннотация на английскомСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To determine whether the appearance of glucose in the fluid spontaneously obtained by the epidural catheter after its insertion during combined intradural-epidural anaesthesia with hyperbaric bupivacaine is a usual occurrence.

PATIENTS AND

METHODS

A prospective, observational study was conducted on 34 patients with combined intradural-epidural anaesthesia in whom an epidural catheter was introduced, after locating the epidural space with a saline solution, inserting a spinal needle and injecting hyperbaric bupivacaine. After observing whether any fluid was spontaneously dripping from it, it was determined if this contained glucose. Withdrawal of the needle and washing its lumen with saline solution, it was checked whether there was glucose in washout. The samples were analysed using a glucose meter. When the motor block disappeared a dose of local anaesthetic was administered through the epidural catheter. The relationship of the demographic parameters with the spontaneous dripping of the epidural catheter was evaluated.

RESULTS

Spontaneous dripping by the epidural catheter after its insertion was observed in 22 patients. All the samples obtained contained glucose. There was glucose in 9 out of 34 epidural needle wash samples. None of the patients suffered from excessive motor-sensory block. There was a statistically significant relationship between patient age (P<.05) and spontaneous dripping by the catheter (the higher the age, more dripping).

CONCLUSION

The finding of glucose in the fluid obtained by the epidural catheter is a frequent occurrence and is of no clinical significance. We propose that it could be due to a leak of cerebrospinal fluid by the dural puncture needle during or after the administering of the hyperbaric bupivacaine and the spillage of this into the epidural space.

Для цитирования: Sánchez Morillo J, Estruch Pérez M J, Balaguer Doménech J, Gallen Martín L, Hernández Cádiz M J, Solaz Roldán C. [The finding of glucose in the fluid obtained by epidural catheter after its insertion during combined intradural-epidural anaesthesia with hyperbaric bupivacaine is a usual occurrence].. Revista espanola de anestesiologia y reanimacion. 2012. DOI: 10.1016/j.redar.2012.04.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.