MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apjo.2025.100198

Медицинская библиотека · Asia-Pacific journal of ophthalmology (Philadelphia, Pa.) · 2025

Comparison of the accuracy of twenty intraocular lens power calculation formulas in long eyes.

Stopyra Wiktor, Voytsekhivskyy Oleksiy, Grzybowski Andrzej

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare the accuracy of twenty intraocular lens (IOL) power calculation formulas in long eyes (26.00-29.99 mm)

DESIGN

Retrospective accuracy and validity analysis

METHODS

The data of patients who underwent uneventful phacoemulsification between August 2019 and July 2024 were reviewed. Pre-surgery IOL power was calculated using Haigis, Holladay 2, SRK/T and Barrett Universal II formulas. Three months after cataract surgery, refraction was measured. Post-surgery IOL power calculations were performed utilizing the following formulas: Castrop, EVO 2.0, Hill-RBF 3.0, Hoffer Q, Holladay 1, Hoffer QST, K6, Kane, Karmona, Ladas Super Formula AI (LSF AI), Naeser 2, Olsen (standalone), PEARL-DGS, T2, VRF and VRF-G. Root mean square absolute error (RMSAE), median absolute error (MedAE) and percentage of eyes with prediction error (PE) within ± 0.25 D, ± 0.50 D, ± 0.75 D and ± 1.00 were calculated.

RESULTS

One hundred fifty-three eyes with axial length ranging between 26.00 mm and 29.47 mm, were studied. The SRK/T formula yielded the lowest RMSAE (0.349) with statistical superiority over Holladay 1 (0.519, P = 0.000), Olsen (standalone) (0.505, P = 0.000) and Hoffer Q (0.497, P = 0.000). In terms of MedAE, the lowest outcome was obtained by VRF-G (0.256) followed by Barrett Universal II, Hill-RBF 3.0 and LSF AI (all equally of 0.260). The highest percentage of eyes with prediction error within ± 0.50 D was achieved by SRK/T (84.97 %) statistically significant vs Holladay 1 (60.78 %), Hoffer Q (64.05 %) and Olsen(standalone) (68.63 %).

CONCLUSIONS

SRK/T has delivered highly accurate results in long eyes. Barrett Universal II, Hill-RBF 3.0, VRF-G and LSF AI are also very true.

Для цитирования: Stopyra Wiktor, Voytsekhivskyy Oleksiy, Grzybowski Andrzej. Comparison of the accuracy of twenty intraocular lens power calculation formulas in long eyes.. Asia-Pacific journal of ophthalmology (Philadelphia, Pa.). 2025. DOI: 10.1016/j.apjo.2025.100198.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.