MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/prs.0000000000012848

Медицинская библиотека · Plastic and reconstructive surgery · 2026

Biosynthetic Versus Synthetic Mesh in Oncologic Ventral Hernia Repair.

Levy Jacob, Wagner Benjamin D, Roberts Arielle, Aschen Seth, Boe Lillian A, Ariyan Charlotte E, Brady Mary S, Allen Robert J, Matros Evan, Mehrara Babak J, Nelson Jonas A

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Ventral hernia repair in oncologic patients is challenging due to poor tissue quality, immunosuppression, malnutrition, and prior operations. Limited data exists comparing the outcomes of biosynthetic (Poly-4-hydroxybutyrate) and synthetic mesh in this population. This study aims to assess the outcomes in patients who undergo hernia repair using one of two mesh types.

METHODS

Patients undergoing ventral hernia repair by the Plastic and Reconstructive Surgery service and general surgery after oncologic resection from 2010 to 2023 were included, with patient records reviewed and cases identified in a prospectively maintained database by the Plastic and Reconstructive Service. Repairs were done in a retrorectus, underlay, or onlay fashion with either biosynthetic or synthetic mesh. Primary endpoints included complication rates (hematoma, infection/cellulitis, wound dehiscence, abscess, seroma) and hernia recurrence.

RESULTS

207 patients underwent repair (102 biosynthetic, 105 synthetic) and were included. Baseline demographics were similar between groups. No significant difference was observed in complication rates (biosynthetic: 24%, synthetic: 18%; p=0.3). Hernia recurrence was noted in 8.8% of biosynthetic and 6.7% of synthetic mesh cases (p>0.6). Subgroup analysis of wound classes II-IV showed consistent results. Up to two years postoperatively, synthetic mesh did not significantly reduce hernia recurrence risk compared to biosynthetic mesh (Subdistribution Hazard Ratio (sHR): 0.66; 95% CI, 0.27-1.59; p=0.4). Bilateral external abdominal oblique release (sHR: 0.31; 95% CI, 0.11-0.87, p=0.026) and retromuscular mesh placement (sHR: 0.08; 95% CI, 0.02, 0.35, p<0.001) exhibited a protective role.

CONCLUSION

Biosynthetic mesh can be considered a reasonable alternative to synthetic mesh in this high-risk population.

Для цитирования: Levy Jacob, Wagner Benjamin D, Roberts Arielle, Aschen Seth, Boe Lillian A, Ariyan Charlotte E, Brady Mary S, Allen Robert J, Matros Evan, Mehrara Babak J, Nelson Jonas A. Biosynthetic Versus Synthetic Mesh in Oncologic Ventral Hernia Repair.. Plastic and reconstructive surgery. 2026. DOI: 10.1097/prs.0000000000012848.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.