DOI 10.3389/frai.2026.1810899

Медицинская библиотека · Frontiers in artificial intelligence · 2026

Assessing GPT-4o in cataract surgery decision-making: appropriateness, consistency, and clinical implications.

Liu Yan, Zhang Chaozhong, Yuan Yuanping, Elken Kalibinur, Lai Jie, Wen Yinuo, Song Linghao, Wang Xinyue, Zhang Min, Chen Zexu, Zhao Zijia, Zhang Yi, Chen Tianhui, Jiang Yongxiang

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the application of large language models (LLMs) in clinical decision-making for cataract surgery using real-world patient data.

METHODS

This retrospective clinical observational study included 74 cataract patients (146 eyes) who underwent phacoemulsification and intraocular lens (IOL) implantation. Preoperative datasets, including clinical findings from ophthalmic imaging, biometric parameters, systemic histories, and lifestyle questionnaires, were processed via GPT-4o. The model was prompted to simulate an experienced cataract surgeon. GPT-4o's IOL recommendations were evaluated for appropriateness with an adjudicated expert consensus and compared against selections made by high- and low-volume cataract surgeons. Appropriateness rates, agreement (Kappa value), and consistency (intraclass correlation coefficient, ICC) were analyzed.

RESULTS

The overall appropriateness rate of GPT-4o for IOL selection was significantly lower than that of human surgeons (37.84% vs. 72.14%, P = 0.001). Subgroup analysis revealed that appropriateness varied by IOL category (P < 0.001), with the highest alignment observed for monofocal IOLs (90.0%) and the lowest for trifocal toric IOLs (9.09%). The presence of ocular or systemic comorbidities was associated with a slight reduction in appropriateness. While agreement analysis indicated poor inter-rater agreement (Kappa < 0.4), GPT-4o demonstrated a slightly higher ICC (0.378) than human surgeons (0.359). However, repeated testing showed significant instability in the model's responses (P = 0.026).

CONCLUSION

GPT-4o demonstrated moderate appropriateness for routine monofocal IOL selection but showed limited appropriateness and consistency in complex, customized scenarios. These findings suggest GPT-4o could assist routine decision-making in cataract surgery, while highlighting the need for further domain-specific fine-tuning and multimodal optimization for advanced cases.

Для цитирования: Liu Yan, Zhang Chaozhong, Yuan Yuanping, Elken Kalibinur, Lai Jie, Wen Yinuo, Song Linghao, Wang Xinyue, Zhang Min, Chen Zexu, Zhao Zijia, Zhang Yi, Chen Tianhui, Jiang Yongxiang. Assessing GPT-4o in cataract surgery decision-making: appropriateness, consistency, and clinical implications.. Frontiers in artificial intelligence. 2026. DOI: 10.3389/frai.2026.1810899.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.