MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.64465

Медицинская библиотека · Cureus · 2024

Acute Treatment of Ischemic Stroke Caused by Stent Graft Thrombosis After Thoracic Endovascular Aortic Repair.

Saito Takashi, Saito Takuya, Ishii Tatsuhito, Homma Kazunari, Kunii Yoshifumi, Koide Masaaki, Ohashi Toshihiko

Клинический случайСтатьяПеревод в очереди

Аннотация

Planning for the acute phase of ischemic stroke in postoperative patients with aortic dissection is difficult from the perspective of concerns about worsening disease related to aortic dissection due to intravenous thrombolytic agents and securing access routes when mechanical thrombectomy is planned. Herein, we report that a 52-year-old man underwent thoracic endovascular aortic repair for acute type B aortic dissection. One year after the procedure, the patient developed a stroke caused by stent graft thrombosis, and computed tomography angiography showed occlusion of the left common carotid artery and left internal carotid artery. Stroke neurologists performed mechanical thrombectomy via a direct approach from the left common carotid artery, and successful recanalization was achieved. Furthermore, ligation of the proximal portion of the left common carotid artery and bypass surgery on the distal portion of the left common carotid artery were performed by cardiovascular surgeons. Although the patient had a postoperative hemorrhagic infarction, he returned to work without a recurrence of stroke after two years of follow-up. A direct carotid artery puncture we performed is an alternative in cases of anatomical difficulty or an unfavorable aortic arch. This case highlights not only the significance of interdisciplinary collaboration between cardiac and neurological specialists but also the impact of training dual-specialty cerebrovascular neurosurgeons on patient outcomes.

Для цитирования: Saito Takashi, Saito Takuya, Ishii Tatsuhito, Homma Kazunari, Kunii Yoshifumi, Koide Masaaki, Ohashi Toshihiko. Acute Treatment of Ischemic Stroke Caused by Stent Graft Thrombosis After Thoracic Endovascular Aortic Repair.. Cureus. 2024. DOI: 10.7759/cureus.64465.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.