m+Medelevator.RU
← Поиск публикаций
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2026

Intra-annular self-expanding or balloon-expandable TAVI in small annuli: the NAVULTRA registry.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cannata Stefano, Sultan Ibrahim, Van Mieghem Nicolas M, Giordano Arturo, Backer Ole De, Byrne Jonathan, Tchétché Didier, Buccheri Sergio, Nombela-Franco Luis, Campante Teles Rui, Barbanti Marco, Barbato Emanuele, Amat Santos Ignacio, Blackman Daniel J, Maisano Francesco, Lorusso Roberto, La Spina Ketty, Millin Antonella, Kliner Dustin E, van den Dorpel Mark, Acerbi Elena, Lulic Davorka, Fayed Hossam, De Biase Chiara, Chavez Solsol Jorge Francisco, Brito Joao, Costa Giuliano, Casenghi Matteo, Cordon Clara Fernandez, Sherwen Amanda, Buzzatti Nicola, Pasta Salvatore, Turrisi Marco, Manca Paolo, Nuzzi Vincenzo, Tamburino Corrado, Bedogni Francesco, Gandolfo Caterina, Latib Azeem

Аннотация

BACKGROUND: Comparative data between self-expanding Navitor (NAV) and balloon-expandable SAPIEN 3 Ultra (ULTRA) transcatheter heart valves (THVs) in patients with small aortic annuli are lacking.

AIMS: This study sought to evaluate outcomes of transcatheter aortic valve implantation (TAVI) using the intra-annular NAV and the ULTRA THVs in severe aortic stenosis patients with small annuli.

METHODS: Patients with an aortic annulus area ≤430 mm2 undergoing TAVI with either NAV or ULTRA from the NAVULTRA registry were included. Propensity-matched analysis was performed for adjustment. Primary endpoints included 1-year mortality, a composite endpoint (all-cause mortality, disabling stroke, or heart failure hospitalisation), and 30-day device-oriented outcomes (severe prosthesis-patient mismatch, moderate or greater paravalvular leak [PVL], mean gradient ≥20 mmHg).

RESULTS: Among 1,617 patients, 524 propensity score-matched pairs were analysed. At 1 year, all-cause mortality was 8.8% with NAV versus 9.0% with ULTRA (adjusted p=0.585), and the composite endpoint occurred in 11.3% versus 11.8%, respectively (adjusted p=0.149). The device-oriented endpoint favoured NAV compared to ULTRA (6.0% vs 29.3%; adjusted p<0.01), with a lower residual transvalvular gradient (7.3 mmHg vs 12.7 mmHg; adjusted p<0.01), and reduced incidence of any prosthesis-patient mismatch (odds ratio 0.27, 95% confidence interval: 0.18-0.43; adjusted p<0.01). However, NAV was associated with higher rates of mild paravalvular leak (NAV 33.5% vs ULTRA 23.2%; adjusted p<0.05) and permanent pacemaker implantation (PPI; NAV 20.1% vs 11.9% ULTRA; adjusted p<0.01).

CONCLUSIONS: In patients with small aortic annuli, TAVI with both NAV and ULTRA provided comparable 1-year clinical outcomes, but NAV showed better haemodynamic performance at the cost of higher rates of mild PVL and PPI.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты