BACKGROUND

Different electrocardiographic (ECG) criteria were proposed to improve ECG-based detection of left ventricular hypertrophy (LVH), but external validation data are limited and their diagnostic performances in different conditions leading to LVH are not extensively assessed.

AIM: to assess the robustness and limitations of ECG scores across distinct LVH phenotypes.

METHODS

The LVH-MORE registry included 408 patients across four cohorts: HTN (n = 103), HCM (n = 104), sAS (n = 101), and controls (n = 100). LVH was defined by echocardiographic left ventricular mass index (LVMi) >115 g/m2 in male subjects and >95 g/m2 in female subjects. Ten ECG criteria were calculated, including Peguero-Lo Presti, Sokolow-Lyon, Cornell, Perugia, Romhilt-Estes, and others. Diagnostic performance was assessed using ROC curves (AUC), sensitivity (Sn), specificity (Sp).

RESULTS

In the HTN cohort, Peguero-Lo Presti achieved the highest AUC for LVH detection (0.752 [95% CI: 0.616-0.888]), with Sn = 31% and Sp = 94%. Other scores showed similar or lower AUCs, with Perugia score showing higher sensitivity (54%). The highest specificity were reached by Sokolow-Lyon and Gubner-Ungerleider (100%). In the HCM cohort, all ECG scores showed modest diagnostic performance (AUC 0.529-0.628). The Perugia and Romhilt-Estes scores achieved the highest sensitivities (94% and 71%, respectively), whereas Sokolow-Lyon showed the highest specificity (90%). In the sAS cohort, AUCs ranged from 0.519 to 0.671. Sensitivity was higher for Perugia (66%) and Romhilt-Estes ≥4 (57%). Highest specificity was shown by Gubner-Ungerleider (95%).

CONCLUSIONS

No single ECG criterion provided consistent diagnostic accuracy across different causes of LVH. Voltage-only ECG scores performed better in HTN patients while multi-parametric scores showed relatively better performance in HCM and sAS.

Для цитирования: Mei Davide Antonio, Serafini Kevin, Imberti Jacopo Francesco, Vitolo Marco, Pollicino Federica, Battigaglia Elisa, Procaccia Gennaro, Cervini Michele, Massari Federico, Barbieri Andrea, Boriani Giuseppe. Detection of left ventricular hypertrophy through ECG: diagnostic performance and comparison of ten ECG scores in different hypertrophic conditions.. European journal of internal medicine. 2026. DOI: 10.1016/j.ejim.2026.106725.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.