Kajal Kamal, Premkumar Madhumita, Izzy Manhal, Kulkarni Anand V, Duseja Ajay Kumar, Divyaveer Smita, Loganathan Sekar, Sihag Bhupendra, Gupta Ankur, Bahl Ajay, Rathi Sahaj, Taneja Sunil, De Arka, Verma Nipun, Sharma Navneet, Kaur Harpreet, Zohmangaihi Deepy, Kumar Vishesh, Bhujade Harish, Chaluvashetty Sreedhara B, Kalra Naveen

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Point-of-care echocardiography (POC-Echo) is an essential intensive care hemodynamic monitoring tool.

AIMS: To assess POC-Echo parameters [i.e., cardiac index (CI), systemic vascular resistance index (SVRI) and cirrhotic cardiomyopathy (CCM) markers] and serum biomarkers in predicting circulatory failure (need for vasopressors) and mortality in patients with acute-on-chronic liver failure (ACLF) having sepsis-induced hypotension.

METHODS

We performed serial POC-Echo within 6 hours (h) of presentation and subsequently at 24, 48 and 72 h in patients with ACLF and sepsis-induced hypotension admitted to our liver intensive care unit. Clinical data, POC-Echo data and serum biomarkers were collected prospectively.

RESULTS

We enrolled 120 patients [59% men, aged 49 ± 12 years, 56% alcohol-related disease and median MELDNa of 30 (27-32)], of whom 68 (56.6%) had circulatory failure, with overall mortality of 60%. CCM was present in 52.5%. The predictors of circulatory failure were CI (aHR -1.5; p = 0.021), N-terminal brain natriuretic peptide (aHR -1.1; p = 0.007) and CCM markers; e' septal mitral velocity (aHR -0.5; p = 0.039) and E/e' ratio (aHR -1.2; p = 0.045). Reduction in CI by 20% and SVRI by 15% at 72 h predicted mortality with a sensitivity of 84% and 72%, and specificity 76% and 65%, respectively (p < 0.001). The MELD-CCM model and CLIF-CCM model were computed as MELDNa + 1.815 × E/e' (septal) + 0.402 × e' (septal) and CLIF-C ACLF + 1.815 × E/e' (septal) + 0.402 × e' (septal), respectively, based on multivariable logistic regression. Both scores outperformed MELDNa (z-score = -2.073, p = 0.038) and CLIF-C ACLF score (z score = -2.683, p-value = 0.007), respectively, in predicting 90-day mortality.

CONCLUSION

POC-Echo measurements such as CCM markers (E/e' and e' velocity) and change in CI reliably predict circulatory failure and mortality in ACLF with severe sepsis. CCM markers significantly enhanced the CLIF-C ACLF and MELDNa predictive performance.

Для цитирования: Kajal Kamal, Premkumar Madhumita, Izzy Manhal, Kulkarni Anand V, Duseja Ajay Kumar, Divyaveer Smita, Loganathan Sekar, Sihag Bhupendra, Gupta Ankur, Bahl Ajay, Rathi Sahaj, Taneja Sunil, De Arka, Verma Nipun, Sharma Navneet, Kaur Harpreet, Zohmangaihi Deepy, Kumar Vishesh, Bhujade Harish, Chaluvashetty Sreedhara B, Kalra Naveen. Cirrhotic cardiomyopathy influences clinical outcomes and enhances performance of conventional risk prediction models in acute-on-chronic liver failure with severe sepsis.. Alimentary pharmacology & therapeutics. 2023. DOI: 10.1111/apt.17695.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.