m+Medelevator.RU
← Поиск публикаций
American journal of ophthalmology · 2025

Which Test Is Best: Evaluation of Traditional and Contemporary Statistical Tests for Analysis of Spherical Equivalent Prediction Error.

СтатьяМногоцентровое исследованиеСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cannon Nathan T, Savini Giacomo, Pantanelli Seth M, Hoffer Kenneth, Aristodemou Petros, Riaz Kamran, Murphy David, Griffin David, Berry Christian, Debellemanière Guillaume, Gauvin Mathieu, Wallerstein Avi, Whang Woong-Joo, Koh Kyungmin, Negishi Kazuno, Hayashi Ken, Hipólito-Fernandes Diogo, Cooke David L

Аннотация

PURPOSE: To characterize the performance of traditional and contemporary statistics tests for analysis of spherical equivalent prediction error (SEQ-PE) after cataract surgery, with regard to test significance and self-consistency.

DESIGN: Comparison of the utility of statistical tests.

METHODS: Subjects: Eyes from 5 academic centers and 2 private practices that had cataract surgery and postoperative manifest refraction between March 2011 and December 2022. SEQ-PE data were randomly divided into subsets with sample sizes of 100, 300, 500, 700, and 2600 eyes. Mean absolute error (MAE), median absolute error (MedAE), SD, root mean squared absolute error (RMSAE), and the proportion of eyes within 0.50 diopters (D) of predicted were calculated for 6 power prediction formulas and analyzed using Friedman post hoc Dunn, Cochran Q post hoc McNemar, Eyetemis, and Wilcox-Holladay-Wang-Koch (WHWK) statistical tests. All tests were corrected for multiple comparisons using the Holm correction.

MAIN OUTCOME MEASURES: The percentage of significant relationships (Percent Significance), proportion of inconsistencies (Inconsistency Ratio), and proportion of self-consistent significant relationships (Significance Index) for each statistical test.

RESULTS: Analysis was performed on 7839 eyes of 7839 patients. WHWK.MAE (42%), WHWK.SD (41%), Eyetemis.MAE (40%), WHWK.RMSAE (39%), and Dunn.MAE (34%) were more robust, respectively, than the remaining 3 tests by Percent Significance (all P < .001). Dunn.MAE had the best Inconsistency Ratio (0.11) in the 100-eye subsets. The same top 5 tests were most robust by Significance Index (0.39, 0.35, 0.35, 0.34, and 0.31, respectively; all P < .02). WHWK.SD and WHWK.RMSAE had the best Significance Indices (both 0.77) in the 2600-eye subsets. McNemar had the poorest Significance Index overall (0.09).

CONCLUSIONS: The 5 high-performing tests produced significant results more often and were also self-consistent. WHWK.MAE and McNemar were highest and lowest performing overall, respectively. Dunn.MAE may be useful in sample sizes <150 eyes.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты