MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00404-025-08169-2

Медицинская библиотека · Archives of gynecology and obstetrics · 2025

Electrosurgical hysteroscopic metroplasty for septate uterus: a single-center retrospective analysis of safety, adhesion rates, and perioperative outcomes.

Piriyev Elvin, Schiermeier Sven, Römer Thomas

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the safety, adhesion rates, and perioperative outcomes of monopolar and bipolar electrosurgical hysteroscopic metroplasty in women with a septate uterus.

METHODS

We conducted a single-center retrospective analysis of 155 consecutive patients who underwent same-session laparoscopy and hysteroscopic septum resection between January 2021 and January 2025. Procedures were performed under surgeon discretion using either a monopolar loop with glycine distension or a bipolar loop with isotonic Ringer's lactate. Postoperative prophylaxis against intrauterine adhesions comprised hyaluronic acid gel-with or without a copper intrauterine device-and, in selected extensive resections, a three-month estrogen-progestin regimen. Endometriosis was diagnosed laparoscopically and, when lesions were excised, confirmed histologically.

RESULTS

The most common indications for the surgery were endometriosis (40.6%), recurrent pregnancy loss (38.0%), and infertility (19.3%). Septal morphology was subseptate in 67.7%, septate in 20.0%, and complete septate in 12.2%, and bipolar energy was used in 65.1% of procedures. No uterine perforations, fluid-overload syndromes, or major hemorrhages occurred, and one case of postoperative endometritis (0.6%) was recorded. Second-look hysteroscopy, performed in 69 patients (44.5%), showed intrauterine adhesions in 3/69 (4.3%; grade I 2.9%, grade II 1.4%); residual septal tissue was observed in 50/69 (72.5%), predominantly in extensive septa. Histologically confirmed endometriosis, identified on concomitant laparoscopy, was present in 126/155 (81.3%) and did not differ across septal types (p = 0.103).

CONCLUSIONS

Monopolar and bipolar electrosurgical hysteroscopic metroplasty showed a good safety profile with negligible major complications, low adhesion rates, and minimal infection. Bipolar systems further enhance safety by enabling isotonic fluid use.

Для цитирования: Piriyev Elvin, Schiermeier Sven, Römer Thomas. Electrosurgical hysteroscopic metroplasty for septate uterus: a single-center retrospective analysis of safety, adhesion rates, and perioperative outcomes.. Archives of gynecology and obstetrics. 2025. DOI: 10.1007/s00404-025-08169-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.