m+Medelevator.RU
← Поиск публикаций
Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis · 2024

Three-Year Outcomes, Risk Factors for Restenosis After Stenting for DVT Combined with Iliac Vein Compression Syndrome.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhang Lin, Jiang Chuli, Chen Zheng, Song Wei, Zhao Yu, Li Fenghe

Аннотация

This study aimed to evaluate the safety and efficacy of pharmacomechanical catheter-directed thrombolysis (PCDT) and stenting for treating acute iliofemoral deep venous thrombosis (DVT) combined with iliac vein compression syndrome (IVCS), and to identify the predictors of stent restenosis. Patients with acute proximal DVT combined with IVCS underwent PCDT and stenting from January 2017 to December 2022 were enrolled. Primary and secondary patency were assessed by duplex ultrasound (DUS). The morbidity of postthrombotic syndrome (PTS) was assessed by the Villalta score. Risk factors for stent restenosis were assessed using univariate and multivariate Cox regression models. Total of 254 patients were included. The mean follow-up time was 36.06 ± 17.66 months. The primary patency rates at 1 year, 3 years, and 5 years were 92.5%±1.7%, 85.4%±2.4%, and 82.4%±2.9%, respectively. The incidence of stent restenosis was 14.2%. Discontinuation of anticoagulants within one year [hazard ratio (HR) = 5.03; P = .048] was the factor associated with acute in-stent thrombosis. Previous DVT history (HR =2.29; P = .037) and stent placement across the inguinal ligament (HR =6.70; P < .001) were identified as independent risk factors significantly associated with stent restenosis. The overall PTS rate was 19.3%. PCDT with stenting is safe and effective for patients with iliofemoral DVT secondary to IVCS, leading to low rates of PTS. Previous DVT history and stents placed across the inguinal ligament may be predictors of stent restenosis. Furthermore, stent restenosis typically occurs within one year and is mainly caused by acute thrombosis due to discontinuation of anticoagulants.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты