Prenatal diagnosis · 2026
MRI in Sheep Model for Myelomeningocele Repair Using a Novel Polymer and Other Dural Patches.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Nagaraj Usha D, Oria Marc, Duru Soner, Lin Chia-Ying, Kline-Fath Beth M, Peiro Jose L
Аннотация
OBJECTIVE: To compare postnatal MRI outcomes after prenatal myelomeningocele repair using three different dural substitutes.
METHOD: 32 sheep fetuses were included, with 34.3%(11/32) serving as healthy controls and the remaining undergoing prenatal spinal lumbar defect creation to recreate a myelomeningocele in the fetus. 90.5% (19/21) of sheep fetuses with surgically created MMC underwent repair using traditional collagen (Durapair) patch (n = 6), HUC matrix (NEOX RT) patch (n = 6), or a novel PLA/PCL patch (n = 7). All sheep underwent brain and spine MRI within 24 h after delivery. Images were reviewed in Research PACS by a pediatric neuroradiologist and were assessed for ventricle size, degree of hindbrain herniation, spinal cord integrity, and fluid collection at the repair site.
RESULTS: There was a significant reduction in hindbrain herniation in all three intervention groups when compared with MMC without prenatal intervention. There was increased incidence of complete spinal cord defect (3/7), pseudomeningocele (5/7) and intraspinal cyst (2/7) at the repair site of the PLA/PCL patch compared with the Durapair and NEOX RT patches.
CONCLUSIONS: This study demonstrates equal efficacy in reducing hindbrain herniation in MMC repair by Durapair, NEOX RT, and PLA/PCL patches by MRI. Future studies analyzing the interaction of the patches with the host tissue in animal models and clinical trials will help to better determine the true safety and efficacy of these novel patches for clinical use.
METHOD: 32 sheep fetuses were included, with 34.3%(11/32) serving as healthy controls and the remaining undergoing prenatal spinal lumbar defect creation to recreate a myelomeningocele in the fetus. 90.5% (19/21) of sheep fetuses with surgically created MMC underwent repair using traditional collagen (Durapair) patch (n = 6), HUC matrix (NEOX RT) patch (n = 6), or a novel PLA/PCL patch (n = 7). All sheep underwent brain and spine MRI within 24 h after delivery. Images were reviewed in Research PACS by a pediatric neuroradiologist and were assessed for ventricle size, degree of hindbrain herniation, spinal cord integrity, and fluid collection at the repair site.
RESULTS: There was a significant reduction in hindbrain herniation in all three intervention groups when compared with MMC without prenatal intervention. There was increased incidence of complete spinal cord defect (3/7), pseudomeningocele (5/7) and intraspinal cyst (2/7) at the repair site of the PLA/PCL patch compared with the Durapair and NEOX RT patches.
CONCLUSIONS: This study demonstrates equal efficacy in reducing hindbrain herniation in MMC repair by Durapair, NEOX RT, and PLA/PCL patches by MRI. Future studies analyzing the interaction of the patches with the host tissue in animal models and clinical trials will help to better determine the true safety and efficacy of these novel patches for clinical use.