MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00259-025-07508-4

Медицинская библиотека · European journal of nuclear medicine and molecular imaging · 2025

Digital versus analogue PET in parathyroid imaging: comparison of PET metrics and machine learning-based characterisation of hyperfunctioning lesions (the DIGI-PET study).

Filippi Luca, Bianconi Francesco, Ferrari Cristina, Linguanti Flavia, Battisti Claudia, Urbano Nicoletta, Minestrini Matteo, Messina Salvatore Gerardo, Buci Lisa, Baldoncini Alfonso, Rubini Giuseppe, Schillaci Orazio, Palumbo Barbara

СтатьяСравнительное исследованиеМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare PET-derived metrics between digital and analogue PET/CT in hyperparathyroidism, and to assess whether machine learning (ML) applied to quantitative PET parameters can distinguish parathyroid adenoma (PA) from hyperplasia (PH).

METHODS

From an initial multi-centre cohort of 179 patients, 86 were included, comprising 89 PET-positive lesions confirmed histologically (74 PA, 15 PH). Quantitative PET parameters-maximum standardised uptake value (SUVmax), metabolic tumour volume (MTV), target-to-background ratio (TBR), and maximum diameter-along with serum PTH and calcium levels, were compared between digital and analogue PET scanners using the Mann-Whitney U test. Receiver operating characteristic (ROC) analysis identified optimal threshold values. ML models (LASSO, decision tree, Gaussian naïve Bayes) were trained on harmonised quantitative features to distinguish PA from PH.

RESULTS

Digital PET detected significantly smaller lesions than analogue PET, in both metabolic volume (1.32 ± 1.39 vs. 2.36 ± 2.01 cc; p < 0.001) and maximum diameter (8.35 ± 4.32 vs. 11.87 ± 5.29 mm; p < 0.001). PA lesions showed significantly higher SUVmax and TBR compared to PH (SUVmax: 8.58 ± 3.70 vs. 5.27 ± 2.34; TBR: 14.67 ± 6.99 vs. 8.82 ± 5.90; both p < 0.001). The optimal thresholds for identifying PA were SUVmax > 5.89 and TBR > 11.5. The best ML model (LASSO) achieved an AUC of 0.811, with 79.7% accuracy and balanced sensitivity and specificity.

CONCLUSIONS

Digital PET outperforms analogue system in detecting small parathyroid lesions. Additionally, ML analysis of PET-derived metrics and PTH may support non-invasive distinction between adenoma and hyperplasia.

Для цитирования: Filippi Luca, Bianconi Francesco, Ferrari Cristina, Linguanti Flavia, Battisti Claudia, Urbano Nicoletta, Minestrini Matteo, Messina Salvatore Gerardo, Buci Lisa, Baldoncini Alfonso, Rubini Giuseppe, Schillaci Orazio, Palumbo Barbara. Digital versus analogue PET in parathyroid imaging: comparison of PET metrics and machine learning-based characterisation of hyperfunctioning lesions (the DIGI-PET study).. European journal of nuclear medicine and molecular imaging. 2025. DOI: 10.1007/s00259-025-07508-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.