Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2024

Two-year follow-up of transcatheter aortic valve replacement in low-risk patients with symptomatic severe bicuspid aortic valve stenosis.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Merdler Ilan, Rogers Toby, Case Brian C, Zhang Cheng, Gordon Paul, Ehsan Afshin, Parikh Puja, Bilfinger Thomas, Buchbinder Maurice, Roberts David, Hanna Nicholas, Ben-Dor Itsik, Reddy Pavan K, Sawant Vaishnavi, Satler Lowell F, Waksman Ron

Аннотация

BACKGROUND: In 2019, the US Food and Drug Administration (FDA) approved transcatheter aortic valve replacement (TAVR) for low-risk patients with symptomatic severe tricuspid aortic stenosis. However, bicuspid aortic valve (BAV) patients were included only in single-arm registries of pivotal low-risk TAVR trials, resulting in limited data for this subgroup.

METHODS: The LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and the first FDA-approved investigational device exemption trial to evaluate the feasibility of TAVR with balloon-expandable or self-expanding valves in low-risk patients with symptomatic severe BAV stenosis. This analysis reports 2-year follow-up, assessing the primary outcome of all-cause mortality and evaluating clinical outcomes.

RESULTS: From 2016 to 2019, a total of 72 low-risk patients diagnosed with symptomatic, severe BAV stenosis underwent TAVR across six centers. Six patients were lost to follow-up. At 2-year follow-up, mortality was 1.5% (1 of 66 patients). Among the remaining 65 patients, four experienced nondisabling strokes (6.2%), while 2 (3.1%) developed infective endocarditis. No new permanent pacemakers were required beyond the 30-day follow-up, and no patients, including those with endocarditis, needed aortic valve re-intervention. At the 2-year echocardiography follow-up (n = 65), 27.8% of BAV patients showed mild aortic regurgitation, with none exhibiting moderate or severe regurgitation. The mean aortic gradient was 12.1 ± 4.1 mmHg, and the mean valve area was 1.7 ± 0.5 cm².

CONCLUSION: The 2-year follow-up confirms commendable clinical outcomes of TAVR in patients with bicuspid aortic stenosis, establishing its evident safety.