MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0000000000000750

Медицинская библиотека · Eye & contact lens · 2021

Bruch Membrane Opening Minimum Rim Width Changes During Scleral Lens Wear.

Samaha Dan, Michaud Langis

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to evaluate the change in Bruch membrane opening minimum rim width (BMO-MRW) during scleral lens (SL) wear.

METHODS

Twenty young white subjects were enrolled (10 women and 10 men); preliminary evaluation consisted of serial measurements of intraocular pressure (IOP) using a dynamic noncontact tonometer (Corvis, Oculus), which also yielded a corneal biomechanical index and central corneal thickness, and BMO-MRW using optical coherence tomography imaging (OCT) imaging (Spectralis, Heidelberg) through 6 hrs to establish normative diurnal curves. The next day, participants were fitted with a 16-mm SL on one eye, and OCT measurements were repeated over the same time span. Statistical analysis was carried out with a two-way analysis of variance. Multiple linear regressions were used to identify significant associations.

RESULTS

The average diurnal variation for BMO-MRW without lenses was -4.65 μm (95% confidence interval [CI], 0.52-8.77) after 6 hours, whereas it decreased by 8 μm (95% CI, 3.87-12.12; P<0.001) after 6 hours of SL wear. The difference between variations after 6 hours was then -3.35 μm (P=0.029). Variation of the BMO-MRW did not significantly correlate with corneal rigidity (CR), central corneal thickness (CCT), and refractive error (r=-0.224, -0.054 and -0.085, respectively).

CONCLUSION

Scleral lens wear induces a statistically significant decrease in BMO-MRW that could potentially be attributed to a change in IOP. The change in BMO-MRW was not affected by CR, CCT, or refractive error. Further studies are needed to better understand the significance of the observed changes at the optic nerve head during scleral lens wear.

Для цитирования: Samaha Dan, Michaud Langis. Bruch Membrane Opening Minimum Rim Width Changes During Scleral Lens Wear.. Eye & contact lens. 2021. DOI: 10.1097/icl.0000000000000750.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.