m+Medelevator.RU
← Поиск публикаций
Journal of endodontics · 2025

Clinical Validation of Smartphone-Enabled Pulse Oximetry for Objective Pulp Vitality Assessment: A Diagnostic Accuracy Study.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Caldeira Celso Luiz, Diaz Zamalloa Stephanie Isabel, Guimaro Sakitani Claudia Regina, Barletta Fernando Branco, Holzhausen Marinella

Аннотация

INTRODUCTION: Pulse oximetry exhibits great potential for use in endodontic diagnosis as an effective method to assess pulp vitality. Cell phone-integrated oximeters represent an emerging alternative that may offer greater accessibility. This study aimed to investigate the relation between pulp oxygenation rates (%SpO2) and clinical diagnosis of healthy pulp (HP), reversible pulpitis (RP), symptomatic irreversible pulpitis (IP), or pulp necrosis (PN), comparing 2 pulse oximeters (conventional [PO1] and mobile-connected).

METHODS: Thirty affected premolars were grouped according to the clinical diagnosis of RP, IP, or PN and compared to vitality diagnosis by %SpO2 obtained by both pulse oximeters: PO1 and by smartphone-based (PO2). For each affected tooth, 2 additional teeth (adjacent and contralateral) with HP were tested. Statistical analysis was performed using one-way ANOVA with Tukey's post-hoc test.

RESULTS: The mean %SpO2 values measured by PO1 were 87.7% for RP, 80.5% for IP, 73.2% for PN, and 91.89% for HP. Corresponding values obtained with PO2 were 85.6% (RP), 79.3% (IP), 72.1% (PN), and 90.1% (HP). Significant differences in %SpO2 were observed among RP, IP, and PN groups (P < .05), but not between healthy control subgroups (adjacent and contralateral). PO1 consistently recorded higher oxygen saturation than PO2 across all clinical conditions (P < .05), demonstrating superior discriminatory capability.

CONCLUSIONS: Both pulse oximeters demonstrated significant clinical value for pulp vitality assessment and differentiation of pulpal inflammation stages and necrosis. The smartphone-adapted oximeter has proven to be comparable to PO1 in diagnostic performance, while offering data collection efficiency and clinical workflow integration.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты