m+Medelevator.RU
← Поиск публикаций
Journal of glaucoma · 2016

Blebitis After EX-PRESS Glaucoma Filtration Device Implantation-A Case Series.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yarovoy Dmitry, Radhakrishnan Sunita, Pickering Terri-Diann, Iwach Andrew G

Аннотация

PURPOSE: To present the management and outcomes of blebitis in patients who underwent EX-PRESS Glaucoma Filtration Device (GFD) implantation.

DESIGN: Retrospective case series.

PARTICIPANTS: The study included 5 patients who developed blebitis following EX-PRESS GFD implantation.

METHODS: Charts of all patients who underwent EX-PRESS GFD implantation at the Glaucoma Center of San Francisco between 2007 and 2013 were reviewed. Five patients with blebitis were identified and their clinical course was recorded.

MAIN OUTCOME MEASURES: Clinical course of blebitis.

RESULTS: Of 325 eyes that underwent EX-PRESS GFD implantation, 5 eyes (1.5%) with blebitis were identified. The mean interval between EX-PRESS GFD surgery and blebitis was 2.3±0.8 years. Four of the 5 eyes with blebitis had potential risk factors for bleb-related infection; 1 had chronic blepharitis, 2 had contact lens use, and one had 2 episodes of bleb leak before blebitis. All patients were treated with topical antibiotics; in addition, 3 received oral antibiotics and 1 received intravitreal antibiotics. None of the patients developed endophthalmitis. One patient had recurrent blebitis, which was treated with topical, oral, and intravitreal antibiotics. None of the patients had the device removed. The mean follow-up time after blebitis was 16.8±8.9 months (range, 10 to 32 mo).

CONCLUSIONS: This case series suggests that blebitis after EX-PRESS GFD implanted under a scleral flap may be treated without removal of the device. Further study is required to determine the optimal method of treating this condition.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты