Improving Diagnostic Robustness of Perfusion MRI in Brain Metastases: A Focus on 3D ROI Techniques and Automatic Thresholding.

Rudzinska-Mistarz Stéphanie, Dissaux Brieg, Marchi Laurie, Roux Anne-Charlotte, Perrot Alexis, Lucia François, Seizeur Romuald, Pradier Olivier, Dissaux Gurvan, Morjani Moncef, Bourbonne Vincent

СтатьяПеревод в очереди

Аннотация

Background

Distinguishing tumor recurrence from radiation necrosis after radiotherapy for brain metastases remains a major diagnostic challenge. Perfusion MRI, particularly the measurement of relative cerebral blood volume (rCBV), is a commonly used technique to differentiate between these two entities. However, variations in the placement of regions of interest (ROIs) affect diagnostic accuracy. This study compares the diagnostic performance of different cerebral perfusion methods, including a novel volumetric 3D ROI method and automatic thresholding, to differentiate tumor recurrence from radiation necrosis.

Methods

We retrospectively analyzed data from 23 patients, including 25 brain metastases treated with stereotactic radiotherapy, who were suspected of local recurrence and had histological confirmation via biopsy or surgical resection. Each patient underwent perfusion MRI before surgery. The diagnostic performance of the different ROI methods (manual and 3D) was evaluated using the area under the ROC curve (AUC), as well as sensitivity and specificity measures. An automatic thresholding method was also applied, generating tumor sub-volumes with predefined cut-off values to determine the rCBV threshold most specific for differentiating relapse from necrosis.

Results

The 3D ROI method, considering the whole lesion and a healthy ROI in the head of the caudate nucleus, demonstrated superior diagnostic performance (AUC = 0.65), outperforming manual methods (AUC = 0.53). Robustness was moderate, with an intraclass correlation coefficient of 0.60 between Syngo.via and IntelliSpace.

Conclusions

The 3D ROI method shows promise in improving diagnostic accuracy in distinguishing tumor recurrence from radiation necrosis. Further studies with standardized protocols and larger populations are needed to validate these results.

Для цитирования: Rudzinska-Mistarz Stéphanie, Dissaux Brieg, Marchi Laurie, Roux Anne-Charlotte, Perrot Alexis, Lucia François, Seizeur Romuald, Pradier Olivier, Dissaux Gurvan, Morjani Moncef, Bourbonne Vincent. Improving Diagnostic Robustness of Perfusion MRI in Brain Metastases: A Focus on 3D ROI Techniques and Automatic Thresholding.. Cancers. 2025. DOI: 10.3390/cancers17132085.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.