MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1123/ijspp.2025-0499

Медицинская библиотека · International journal of sports physiology and performance · 2026

Repeatability of Upper and Lower Body Force Plate Assessments in Canadian University Swimmers: Implications for Athlete Monitoring and Return-to-Swim Testing.

McKenzie Mark, Boon-van Mossel Nathan, McClean Zachary J, Jordan Matthew J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The shoulder accounts for over 50% of injuries in swimming, making it the most injured body part. However, little research has examined shoulder girdle strength and how weakness or compensations may predispose swimmers to injury. Additionally, despite established muscle testing methods in other sports, there is a wide gap in the literature regarding strength testing in competitive swimmers, notably in the shoulder.

PURPOSE: To establish the repeatability of the athletic shoulder (ASH) test, the ballistic push-up test, and the unilateral and bilateral countermovement jump (CMJ) test in male and female university swimmers.

STUDY

DESIGN

Test-retest repeatability study.

METHODS

University swimmers (n = 32; female: n = 18) completed strength tests on 2 occasions separated by a 60-minute rest period. Participants completed a standardized warm-up. The force plate testing battery consisted of isometric shoulder flexion (ASH test) at 180° and 135°, ballistic push-up testing, and bilateral and unilateral CMJ testing. Intrasession and intersession repeatability were assessed using intraclass correlation coefficients (ICCs) and coefficients of variation (CV).

RESULTS

All outcome measures for CMJ and ballistic push-up testing showed good (ICC = .80-.89, CV < 10%) or excellent (ICC > .90, CV < 5%) repeatability, although the ASH test demonstrated good-to-excellent relative repeatability (ICC = .87-.90) but greater absolute variability (CV > 10%).

CONCLUSION

CMJ and ballistic push-up testing on a force plate are suitable for athlete monitoring in competitive swimming. The ASH test demonstrated greater variability between sessions, highlighting the need for further evaluation prior to its integration into athlete monitoring assessments.

Для цитирования: McKenzie Mark, Boon-van Mossel Nathan, McClean Zachary J, Jordan Matthew J. Repeatability of Upper and Lower Body Force Plate Assessments in Canadian University Swimmers: Implications for Athlete Monitoring and Return-to-Swim Testing.. International journal of sports physiology and performance. 2026. DOI: 10.1123/ijspp.2025-0499.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.