Optometry and vision science : official publication of the American Academy of Optometry · 1998
Evaluation of mild, moderate, and advanced keratoconus using ultrasound pachometry and the EyeSys videokeratoscope.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Watters G A, Owens H
Аннотация
BACKGROUND: The absolute accuracy of videokeratoscope (VKS) mapping of keratoconus is still in question, with contact lens-induced corneal warpage and chalazion having been shown to resemble this condition closely. Corneal thinning is investigated as a further aid to the diagnosis and description of keratoconus.
METHODS: The diagnosis of keratoconus in 41 individuals was verified by measuring the corneal thickness difference (I-S difference) between two disparate corneal locations, one inferior to (I) and one superior to (S) the corneal apex, using a Humphrey model 870 Ultrasound pachometer. Corresponding measures of I-S radii were made using radius values obtained from the EyeSys VKS.
RESULTS: A comparison between I-S pachometry and I-S radius demonstrated a marginally increased sensitivity for the latter measurement. Using 95% confidence levels from normative pachometric data, classification of severity of keratoconus is proposed as follows: (1) keratoconus suspect/early keratoconus: I-S pachometry 75 to 100 microns; (2) moderate keratoconus: 100 to 125 microns; and (3) advanced keratoconus: > 125 microns.
CONCLUSION: I-S pachometry can be used as a descriptor of keratoconus.
METHODS: The diagnosis of keratoconus in 41 individuals was verified by measuring the corneal thickness difference (I-S difference) between two disparate corneal locations, one inferior to (I) and one superior to (S) the corneal apex, using a Humphrey model 870 Ultrasound pachometer. Corresponding measures of I-S radii were made using radius values obtained from the EyeSys VKS.
RESULTS: A comparison between I-S pachometry and I-S radius demonstrated a marginally increased sensitivity for the latter measurement. Using 95% confidence levels from normative pachometric data, classification of severity of keratoconus is proposed as follows: (1) keratoconus suspect/early keratoconus: I-S pachometry 75 to 100 microns; (2) moderate keratoconus: 100 to 125 microns; and (3) advanced keratoconus: > 125 microns.
CONCLUSION: I-S pachometry can be used as a descriptor of keratoconus.