Lambert-Eaton myasthenia syndrome: specified description of a response pattern to low-frequency repetitive nerve stimulation.

Zhou Xiajun, Wang Ze, Zhu Ying, Zhu Desheng, Xie Chong, Guan Yangtai

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

We aimed to specify and quantify the characteristics of the decrement in low-frequency repetitive nerve stimulation response in Lambert-Eaton myasthenia syndrome (LEMS) and compare it to those of myasthenia gravis (MG).

PATIENTS AND

METHODS

We retrospectively reviewed 18 patients with LEMS and 24 patients with MG. Ten consecutive stimulations were applied at 3 Hz to the abductor pollicis brevis. We determined the position of the smallest wave in the stimulation sequence, and we calculated the decrement and recovery.

RESULTS

The median sequential order of the minimum wave was 8 in the LEMS group and 5 in the MG group (p < 0.001). The median decrement in the LEMS group was 36.7%, while that in the MG group was 21.0% (p = 0.047). The recovery percentage was 1.4% in the LEMS group and 3.5% in the MG group (p = 0.001). The area under the curve for the sequential order of the minimum wave was 0.90, and the reciprocal optimum cut-off point was 6.5.

CONCLUSIONS

We elucidated a pattern with a delayed nadir and subsequent poor recovery, featuring a low-frequency decrement; furthermore, we determined the most likely sequential order of the minimum wave in patients with LEMS, and the indicator was useful for differentiation.

Для цитирования: Zhou Xiajun, Wang Ze, Zhu Ying, Zhu Desheng, Xie Chong, Guan Yangtai. Lambert-Eaton myasthenia syndrome: specified description of a response pattern to low-frequency repetitive nerve stimulation.. Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology. 2020. DOI: 10.1016/j.jelekin.2020.102437.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.