Аннотация

PURPOSE: We compared three-dimensional time-of-flight MR angiograms obtained before and after acetazolamide administration to evaluate whether use of this drug could improve visualization of small peripheral intracranial arteries and atherosclerotic stenosis.

METHODS

For evaluation of small peripheral arteries, 10 patients with clinical diagnosis of ischemic cerebrovascular disease and 10 healthy volunteers were investigated, and for evaluation of stenosis, another 6 patients were investigated. Vascular images were obtained by three-dimensional time-of-flight MR angiography. After a baseline scan, 17 mg/kg acetazolamide was injected intravenously and the second scan was performed 20 minutes later.

RESULTS

Several small peripheral arteries that had not been seen on the baseline images were visible on the acetazolamide images without any augmentation of the background signals. Stenotic lesions in the main trunks of the major cerebral arteries were detected more clearly on acetazolamide images.

CONCLUSIONS

Acetazolamide improves visualization of small peripheral intracranial arteries and sensitivity in detecting atherosclerotic stenosis in the main trunk of major cerebral artery by three-dimensional time-of-flight MR angiography without changing MR apparatus and software.

Для цитирования: Mandai K, Sueyoshi K, Fukunaga R, Nukada M, Ohtani F, Araki Y, Tsukaguchi I, Abe H. Acetazolamide challenge for three-dimensional time-of-flight MR angiography of the brain.. AJNR. American journal of neuroradiology. 1994.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.