Nutrition, metabolism, and cardiovascular diseases : NMCD · 2026
Association between device-measured physical activity and aortic aneurysm risk: a prospective cohort study of 93165 UK biobank participants.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yan Shaohua, Zhu Changyan, Hu Yuqiu, Guo Wei, Liu Yujia, Wang Ting, Jin Shuyu, Hou Yangfeng, Wang Hua
Аннотация
BACKGROUND AND AIM: Aortic aneurysm (AA) is a life-threatening vascular disease with high fatality upon rupture. While physical activity (PA) reduces cardiovascular risk, its role in AA prevention remains uncertain, particularly when assessed objectively.
METHODS AND RESULTS: We analyzed 93,165 UK Biobank participants (56% women; median age 57 years) with valid 7-day wrist-worn accelerometer data. PA was categorized as light (LPA), moderate (MPA), vigorous (VPA), and moderate-to-vigorous (MVPA). Diagnosed AA was ascertained through linked hospital, death, and primary care records. Cox models estimated hazard ratios (HRs) for AA across quartiles and per-standard deviation (SD) increments, with adjustment for demographic, lifestyle, and cardiometabolic factors. Over a median 7.9-year follow-up, 499 clinically recorded AA cases occurred. Higher accelerometer-measured PA was inversely associated with AA risk. Per-SD increments in total PA, MPA, VPA, and MVPA corresponded to 17%, 22%, 19%, and 23% lower risks, respectively. Compared with the lowest quartile, the highest MVPA quartile had a 44% lower AA risk (HR = 0.56, 95% CI 0.42-0.76). Subtype analyses revealed stronger protective effects for abdominal aortic aneurysm (AAA) than thoracic aortic aneurysm (TAA), while LPA was not significantly associated.
CONCLUSIONS: These findings demonstrate that higher levels of accelerometer-measured MVPA are robustly associated with a decreased risk of clinically detected AA in a dose-dependent manner. The associations were particularly pronounced for AAA. This study provides objective evidence supporting the potential benefits of MVPA for aortic health.
METHODS AND RESULTS: We analyzed 93,165 UK Biobank participants (56% women; median age 57 years) with valid 7-day wrist-worn accelerometer data. PA was categorized as light (LPA), moderate (MPA), vigorous (VPA), and moderate-to-vigorous (MVPA). Diagnosed AA was ascertained through linked hospital, death, and primary care records. Cox models estimated hazard ratios (HRs) for AA across quartiles and per-standard deviation (SD) increments, with adjustment for demographic, lifestyle, and cardiometabolic factors. Over a median 7.9-year follow-up, 499 clinically recorded AA cases occurred. Higher accelerometer-measured PA was inversely associated with AA risk. Per-SD increments in total PA, MPA, VPA, and MVPA corresponded to 17%, 22%, 19%, and 23% lower risks, respectively. Compared with the lowest quartile, the highest MVPA quartile had a 44% lower AA risk (HR = 0.56, 95% CI 0.42-0.76). Subtype analyses revealed stronger protective effects for abdominal aortic aneurysm (AAA) than thoracic aortic aneurysm (TAA), while LPA was not significantly associated.
CONCLUSIONS: These findings demonstrate that higher levels of accelerometer-measured MVPA are robustly associated with a decreased risk of clinically detected AA in a dose-dependent manner. The associations were particularly pronounced for AAA. This study provides objective evidence supporting the potential benefits of MVPA for aortic health.