DOI 10.1016/j.jtcvs.2023.12.018

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2023

Age is superior to aortopathy phenotype as a predictor of aortic mechanics in patients with bicuspid valve.

Thompson Matthew A, Kramer Benjamin, Tarraf Samar A, Vianna Emily, Gillespie Callan, Germano Emidio, Gentle Brett, Cikach Frank, Lowry Ashley M, Pande Amol, Blackstone Eugene, Hargrave Jennifer, Colbrunn Robb, Bellini Chiara, Roselli Eric E

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Bicuspid aortic valve (BAV) aortopathy is defined by 3 phenotypes-root, ascending, and diffuse-based on region of maximal aortic dilation. We sought to determine the association between aortic mechanical behavior and aortopathy phenotype versus other clinical variables.

METHODS

From August 1, 2016, to March 1, 2023, 375 aortic specimens were collected from 105 patients undergoing elective ascending aortic aneurysm repair for BAV aortopathy. Planar biaxial data (191 specimens) informed constitutive descriptors of the arterial wall that were combined with in vivo geometry and hemodynamics to predict stiffness, stress, and energy density under physiologic loads. Uniaxial testing (184 specimens) evaluated failure stretch and failure Cauchy stress. Boosting regression was implemented to model the association between clinical variables and mechanical metrics.

RESULTS

There were no significant differences in mechanical metrics between the root phenotype (N = 33, 31%) and ascending/diffuse phenotypes (N = 72, 69%). Biaxial testing demonstrated older age was associated with increased circumferential stiffness, decreased stress, and decreased energy density. On uniaxial testing, longitudinally versus circumferentially oriented specimens failed at significantly lower Cauchy stress (50th [15th, 85th percentiles]: 1.0 [0.7, 1.6] MPa vs 1.9 [1.3, 3.1] MPa; P < .001). Age was associated with decreased failure stretch and stress. Elongated ascending aortas were also associated with decreased failure stress.

CONCLUSIONS

Aortic mechanical function under physiologic and failure conditions in BAV aortopathy is robustly associated with age and poorly associated with aortopathy phenotype. Data suggesting that the root phenotype of BAV aortopathy portends worse outcomes are unlikely to be related to aberrant, phenotype-specific tissue mechanics.

Для цитирования: Thompson Matthew A, Kramer Benjamin, Tarraf Samar A, Vianna Emily, Gillespie Callan, Germano Emidio, Gentle Brett, Cikach Frank, Lowry Ashley M, Pande Amol, Blackstone Eugene, Hargrave Jennifer, Colbrunn Robb, Bellini Chiara, Roselli Eric E. Age is superior to aortopathy phenotype as a predictor of aortic mechanics in patients with bicuspid valve.. The Journal of thoracic and cardiovascular surgery. 2023. DOI: 10.1016/j.jtcvs.2023.12.018.