Flow diversion treatment of aneurysms of the complex region of the anterior communicating artery: which stent placement strategy should 'I' use? A single center experience.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pagiola Igor, Mihalea Cristian, Caroff Jildaz, Ikka Léon, Chalumeau Vanessa, Yasuda Thomas, Marenco de la Torre Joaquin, Iacobucci Marta, Ozanne Augustin, Gallas Sophie, Marques Marcio Chaves, Carrete Henrique, Frudit Michel Eli, Moret Jacques, Spelle Laurent

Аннотация

BACKGROUND: Aneurysms of the anterior communicating artery (ACoA) are difficult to treat with coiling or clipping because of the anatomical variation in this region. Flow diversion represents a feasible treatment, but no consensus exists as to which stent deployment technique is more suitable.

METHODS: All patients with ACoA aneurysms treated with flow diverters between April 2014 and November 2018 were retrospectively analyzed. Aneurysm characteristics, follow-up results, and clinical outcome data were recorded, and a new classification comparing the diameters of both A1 segments is proposed: H1=same diameters; H2=<50% difference in diameters; H3= ≥50% difference; and Y=no A1 segment.

RESULTS: We analyzed 30 procedures in 30 patients with ACoA aneurysms, including 16 ruptured aneurysms treated with coiling embolization and 4 previously unruptured aneurysms (two Medina and two Woven EndoBridge devices). Adequate aneurysm occlusion occurred in 86.9%; one patient (3.3%) experienced symptomatic ischemic stroke. The global thromboembolic complications for each group were 17.6% (H1), 25% (H2), and 60% (H3).

CONCLUSION: Flow diversion treatment in this region is safe, feasible, and effective. The most suitable anatomical configuration for flow diverter treatment seems to be the H1 configuration where the 'I technique' is suitable (from an A1 segment to the ipsilateral A2). There is a tendency that the H3 configuration is not a good indication for flow diverter treatment. However, further studies are needed to evaluate the feasibility of this anatomical classification and the reproducibility of our findings.