MedElevator Войти в исследования
← Поиск публикаций

DOI 10.36660/abc.20230337

Медицинская библиотека · Arquivos brasileiros de cardiologia · 2024

Predictors of Appropriate Therapies and Death in Patients with Implantable Cardioverter-Defibrillator and Chronic Chagas Heart Disease.

Pereira Francisca Tatiana Moreira, Rocha Eduardo Arrais, Gondim Davi Sales Pereira, Almeida Rosa Livia Freitas de, Pires Neto Roberto da Justa

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There are few retrospective and prospective studies on implantable cardioverter-defibrillators (ICD) in primary and secondary prevention of sudden death in chronic Chagas heart disease (CCHD).

OBJECTIVES

To describe the long-term evolution of patients with CCHD and ICD and to identify and analyze predictors of mortality and appropriate device therapy in this population.

METHODS

This was a historical prospective study with 117 patients with ICD and CCHD. Devices were implanted from January 2003 to December 2021. Predictors of appropriate therapies and long-term mortality were identified and analyzed. The level of statistical significance was p < 0.05.

RESULTS

Patients (n = 117) had a median follow-up of 61 months (25 to 121 months); they were predominantly male (74%), with a median age of 55 years (48 to 64 years). There were 43.6% appropriate shocks, 26.5% antitachycardia pacing (ATP), and 51% appropriate therapies. During follow-up, 46 patients (39.7%) died. Mortality was 6.2% person-years (95% confidence interval [CI]: 4.6 to 8.3), with 2 sudden deaths during follow-up. Secondary prevention (hazard ratio [HR] 2.1; 95% CI: 1.1 to 4.3; p = 0.029) and ejection fraction less than 30% (HR 1.8; 95% CI: 1.1 to 3.1; p < 0.05) were predictors of appropriate therapies. Intermediate Rassi score showed a strong association with the occurrence of ATP alone (p = 0.015). Functional class IV (p = 0.007), left ventricular ejection fraction < 30 (p = 0.010), and age above 75 years (p = 0.042) were predictors of total mortality.

CONCLUSION

ICDs in CCHD showed a high incidence of appropriate activation, especially in patients with secondary prevention, low left ventricular ejection fraction, and intermediate Rassi score. Patients with congestive heart failure, elevated functional class, and age over 75 years showed elevated mortality. Survival function of patients with implantable cardioverter-defibrillators and chronic Chagas heart disease. A - According to New York Heart Association functional class; B - According to left ventricular ejection fraction; C - According to Rassi score. D - According to age. CCHD: chronic Chagas heart disease; HR: hazard ratio; ICD: implantable cardioverter-defibrillator.

Для цитирования: Pereira Francisca Tatiana Moreira, Rocha Eduardo Arrais, Gondim Davi Sales Pereira, Almeida Rosa Livia Freitas de, Pires Neto Roberto da Justa. Predictors of Appropriate Therapies and Death in Patients with Implantable Cardioverter-Defibrillator and Chronic Chagas Heart Disease.. Arquivos brasileiros de cardiologia. 2024. DOI: 10.36660/abc.20230337.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.