MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fsurg.2026.1774737

Медицинская библиотека · Frontiers in surgery · 2026

Body surface area-adjusted median nerve cross-sectional area and multimodal ultrasound improve diagnosis of carpal tunnel syndrome.

Yu Boyi, Du Jie, Liu Yansong, Zhang Lili, Li Hongyu, Sun Fangfang, Liu Lifang, Zhang Chao, Liu Xinyue, Hu Feng, Shao Linlin, Sun Mengqin, Zhao Lirong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To evaluate the diagnostic performance of high-frequency ultrasound combined with Superb Microvascular Imaging (SMI) and Shear Wave Elastography (SWE) for carpal tunnel syndrome (CTS), and to develop an individualized diagnostic approach using a body surface area (BSA)-adjusted median nerve CSA at the pisiform level.

MATERIALS AND

METHODS

This retrospective study included 47 wrists with carpal tunnel syndrome (CTS) and 94 control wrists. Median nerve cross-sectional area (CSA) was measured at four anatomical sites. Superb Microvascular Imaging (SMI) and Shear Wave Elastography (SWE) were used to assess intraneural vascularity and stiffness, respectively. A linear regression model was developed to estimate the expected CSA at the pisiform level based on body surface area (BSA), and a BSA-based Z-score was calculated accordingly. Receiver operating characteristic (ROC) analyses were performed to compare the diagnostic performance of (i) a fixed CSA cutoff at the pisiform level, (ii) the BSA-based Z-score, and (iii) a combined SMI + SWE logistic regression model.

RESULTS

Ultrasound parameters differed significantly between the CTS and control groups (P < 0.05). The BSA-based Z-score derived from the CSA at the pisiform level yielded an AUC of 0.924 (95% CI 0.879-0.969) and improved specificity (83%; 95% CI 0.738-0.899) compared with the fixed CSA cutoff (75%; 95% CI 0.644-0.829). In multivariable analysis, SMI- and SWE-derived parameters remained independent predictors of CTS (P < 0.001). The combined SMI + SWE logistic regression model demonstrated the best diagnostic performance (AUC 0.944; 95% CI 0.906-0.982), with 83% sensitivity (95% CI 0.692-0.924) and 90% specificity (95% CI 0.826-0.955).

CONCLUSION

High-frequency ultrasound combined with Superb Microvascular Imaging (SMI) and Shear Wave Elastography (SWE) enables accurate, noninvasive evaluation of CTS. A BSA-based CSA Z-score improves specificity in CSA-based diagnosis, and integrating SMI and SWE further enhances overall diagnostic performance.

Для цитирования: Yu Boyi, Du Jie, Liu Yansong, Zhang Lili, Li Hongyu, Sun Fangfang, Liu Lifang, Zhang Chao, Liu Xinyue, Hu Feng, Shao Linlin, Sun Mengqin, Zhao Lirong. Body surface area-adjusted median nerve cross-sectional area and multimodal ultrasound improve diagnosis of carpal tunnel syndrome.. Frontiers in surgery. 2026. DOI: 10.3389/fsurg.2026.1774737.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.