MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s26144568

Медицинская библиотека · Sensors (Basel, Switzerland) · 2026

Sensor-Based Assessment of Quadriceps EMG-Amplitude-to-Torque Ratios at Different Knee Angles: An Exploratory Cross-Sectional Study.

Zhang Zhaoxiang, Tomicka Małgorzata, Guo Xiaodan, Li Mingmao, Krawczynski Marcin, Aschenbrenner Piotr, Kawczyński Adam

СтатьяПеревод в очереди

Аннотация

Surface electromyography (sEMG) normalized to mechanical output can describe electrical activation amplitude relative to torque, but such ratios should not be interpreted automatically as neuromuscular efficiency. This exploratory cross-sectional study compared quadriceps activation-to-torque ratios at 45° and 75° knee flexion and examined hypothesis-generating associations with countermovement jump (CMJ) outcomes. Seventeen participants performed two brief unilateral maximal isometric knee-extension trials at each angle. Wireless sEMG from the vastus lateralis (VL), vastus medialis (VM), and rectus femoris (RF) and Biodex torque were acquired separately and manually matched by participant, knee angle, and test set. Ratios were calculated as Noraxon-exported mean EMG amplitude divided by Biodex average peak torque. Ratios were higher at 45° than at 75° for VL (mean difference = 0.74 μV/(N·m), BCa 95% CI: 0.34-1.34; Holm-adjusted p = 0.020), VM (0.52, 0.09-0.72; p = 0.009), and RF (0.69, 0.22-1.32; p = 0.028). Exploratory Spearman correlations with CMJ outcomes ranged from -0.38 to 0.32 and were nonsignificant after false-discovery-rate correction. The findings indicate protocol-specific, angle-dependent differences, whereas CMJ associations remain inconclusive and require larger, reliability-focused studies with synchronized acquisition and fully documented signal processing.

Для цитирования: Zhang Zhaoxiang, Tomicka Małgorzata, Guo Xiaodan, Li Mingmao, Krawczynski Marcin, Aschenbrenner Piotr, Kawczyński Adam. Sensor-Based Assessment of Quadriceps EMG-Amplitude-to-Torque Ratios at Different Knee Angles: An Exploratory Cross-Sectional Study.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26144568.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.