m+Medelevator.RU
← Поиск публикаций
The Annals of otology, rhinology, and laryngology · 2025

Tracheobronchial Foreign Body Extraction in a Preterm Infant via Choledochoscope: A Case Report and Literature Review.

СтатьяКлинический случайОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Prstačić Ratko, Pasini Miram, Sindičić Dessardo Nada, Đenović Mateja, Grizelj Ruža

Аннотация

OBJECTIVES: Tracheobronchial foreign body (TFB) extraction in premature neonates poses unique challenges due to their delicate respiratory system, making the TBF extraction a critical and high-stakes intervention. TFBs in this patient population are mostly iatrogenic. There are only a few reports in the literature describing the management of TFBs in premature neonates. To the best of our knowledge, this represents the first report using a flexible choledochoscope for TFB extraction.

METHODS: A retrospective chart review was conducted on a case of a preterm infant who underwent successful extraction of a tracheobronchial foreign body.

RESULTS: A premature neonate born at 25 weeks 2/7 days gestation with a birth weight of 780 g was intubated after delivery. Following extubation to non-invasive ventilation, a control chest radiograph revealed atelectasis of the right lower lobe and a TFB of tubular structure measuring 20 mm × 1.5 mm in the right main bronchus. Diagnostic flexible bronchoscopy was performed and extraction with graspers via rigid bronchoscope was attempted but failed. Subsequently, a bedside procedure in the Neonatal intensive care unit (NICU) was performed using a 7.5 Fr flexible choledochoscope through the endotracheal tube (ETT). TFB was successfully extracted with graspers and upon extraction, it was confirmed to be the distal 2 cm segment of the closed-circuit endotracheal suction system. The infant made full recovery.

CONCLUSION: We report a method that provides a safe means of TFB extraction with a successful outcome. The insights gathered from this review are intended to contribute valuable knowledge that can enhance the management of TFBs in preterm infants.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты